EasyManuals Logo

Honeywell RET97C Series User Manual

Honeywell RET97C Series
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
7
Alternate Wiring (For Heat Pumps Only)
2
3
3
4
5
5
6
6
Leave metal jumper in place, connecting R & Rc terminals.
If your old thermostat had both
V and VR wires, stop now and contact a
qualified contractor for help.
If your old thermostat had separate
O and B wires, attach the B wire to
the
C terminal. If another wire is attached to the C terminal, stop now and
contact a qualified contractor for help.
If your old thermostat had
Y1, W1 and W2 wires, stop now and contact a
qualified contractor for help.
If
L terminal is used, C terminal wire must be connected (contact a
contractor if there is no
C wire).
If
E and Aux terminals do not each have a wire connected, use a small
piece of wire to connect them to each other.
5
6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell RET97C Series and is the answer not in the manual?

Honeywell RET97C Series Specifications

General IconGeneral
BrandHoneywell
ModelRET97C Series
CategoryThermostat
LanguageEnglish

Related product manuals