RTH2510/RTH2410
17 69-2421ES—03
WIRING ASSISTANCE TROUBLESHOOTING
When correct setting is selected, press both s and t
to display next function.
Compressor Protection
Press the s or t button to select compressor protec-
tion:
Damage can occur if the compressor is
restarted too soon after shutdown. This fea-
ture forces the compressor to wait 5 minutes
before restarting. During the wait time, the
message Cool On or Heat On flashes on the
screen. When the safe wait time has elapsed,
the message stops flashing and the compres-
sor turns on.
1 On
0 Off
4
1