EasyManua.ls Logo

Honeywell RTH9585 - Pre-occupancy purge; Compressor protection; Auto changeover

Honeywell RTH9585
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
69-2715EF—07 26
Pre-occupancy purge
This business use feature turns on the
fan 1 to 3 hours before each “occupied”
time period, to provide a comfortable
work environment when you arrive.
Compressor protection
The thermostat keeps the compressor
off for a few minutes before restarting,
to prevent equipment damage. During
this “off time, the message “waiting for
equipment” is displayed on screen.
Auto changeover
This feature is used in climates where
both air conditioning and heating are used
on the same day.
When the system is set to Automatic, the
thermostat automatically selects heating
or cooling depending on the indoor
temperature.
Heat and cool settings must be at least
3 degrees apart. The thermostat will
automatically adjust settings to maintain
this 3-degree separation.
Note: Select Auto Changeover on the
Heating and Cooling System Changeover
screen under Advanced Preferences. See
“Setting advanced preferences” on page
27.

Table of Contents

Other manuals for Honeywell RTH9585

Related product manuals