4
Home and Building Control Home and Building Control Helping You Control Your World
Honeywell Inc. Honeywell Limited—Honeywell Limitée
1985 Douglas Drive North 740 Ellesmere Road
Golden Valley, MN 55422 Scarborough, Ontario
M1P 2V9
Printed in U.S.A.
QUALITY IS KEY
Checkout
HEATING
Turn down temperature setting to lowest point. If sub-
base is used, move system switch to HEAT position.
Raise temperature setting until heating equipment starts.
This point should be at room temperature as indicated on
the thermometer. Turn back dial slowly. Heating equip-
ment should stop when dial has been turned below room
temperature.
COOLING
CAUTION
1. Do not operate cooling if outdoor temperature
is below 50° F [10° C]. Refer to manufac-
turer recommendations.
2. Allow five-minute off-time after compressor
has been run to avoid compressor damage.
If T87F controls cooling, move system switch (if
used) to call for COOL and lower setting until cooling
equipment starts. Raise setting above room temperature
and cooling system should shut down. Make certain all
equipment responds properly to the thermostat.
!

Other manuals for Honeywell T87F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell T87F and is the answer not in the manual?

Honeywell T87F Specifications

General IconGeneral
Temperature Range40°F to 90°F (4°C to 32°C)
Voltage24V AC
ApplicationResidential
MountingWall mount
Switching ActionSPST
Power SourceHardwired
DisplayAnalog
ColorWhite
Control TypeMechanical
CompatibilityHeating systems
Accuracy±2°F
Weight0.5 lb