EasyManua.ls Logo

Honeywell TH8320R1003 Vision Pro 8000 User Manual

Honeywell TH8320R1003 Vision Pro 8000
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
PRODUCT DATA
68 0312 01
VisionPRO
®
8000 with RedLINK™
APPLICATION
The VisionPRO® 8000 with RedLINK™ features an effortless,
7-Day programmable touchscreen thermostat that provides
control of temperature, humidification, dehumidification, and
ventilation for up to 4 Heat/2 Cool heat pump systems or up to
3 Heat/2 Cool conventional systems for residential and
commercial applications.
FEATURES
RedLINK™ Compatible
Increase your content and profit per job by including
RedLINK™ accessories that meet your customers comfort
and convenience needs. RedLINK accessories include the
Wireless Outdoor Sensor, Portable Comfort Control (PCC),
Equipment Interface Module (EIM), RedLINK Internet
Gateway, Wireless Indoor Sensor, TrueSTEAM™ humidi-
fier with Wireless Adapter, TrueZONE™ zoning panel with
Wireless Adapter, Vent Boost Remote and Entry/Exit
Remote.
Customizable Service Reminders
Set up to 10 service reminders. Choose from the pre-set
options or customize your own. Reminders can be based
on date or the outdoor temperature.
Universal Inputs
Thermostat - S1
EIM - S1, S2, S3, S4
Assignable inputs allow you to setup Indoor and Outdoor
Temperature Sensors, Discharge and Return Air Sensors
or Dry Contact Devices. Dry Contact Devices can be used
to trip pre-set or customized alerts on the thermostat home
screen. Note: Dry Contact Alerts require an Equipment
Interface Module (EIM).
User Interaction Log
The interaction log stores history of thermostat setting
changes including temperature, system and installer setup.
You can use the interaction log to save time by determining
if the issue is a system error or an accidental user error.
The Interaction Log is only viewable on a computer after
you download it from the thermostat to a microSD card.
Selectable for Residential and Light Commercial
Applications
One thermostat does it all to meet the needs of Residential
and Light Commercial applications. Simply select Residen-
tial or Commercial during the installer setup. If Commercial
is selected, the thermostat will use commercial language,
meet building codes and offer 365 day holiday scheduling.
MicroSD Card Port for Quick Installer Setup
Save time by using a microSD card to upload installer set-
tings and service reminders in one simple step.
Selectable Sensors
When paired with a Wireless Indoor Sensor(s) you have
the ability to choose which sensor(s) to use for tempera-
ture, humidification and dehumidification. They can be
used in combination for temperature averaging—or individ-
ually—to condition humidity levels in separate spaces.

Table of Contents

Questions and Answers:

Honeywell TH8320R1003 Vision Pro 8000 Specifications

General IconGeneral
ModelTH8320R1003
BrandHoneywell
ProgrammableYes
Temperature Accuracy+/- 1°F
ChangeoverAuto or Manual
Humidity ControlNo
BacklightYes
DisplayTouchscreen
StagesUp to 3 Heat/2 Cool
Power SourceBattery or Hardwired
CompatibilityHeat Pump
Programmability7-Day Programmable
Terminal DesignationsR, C, Y, G, O/B, L, S1, S2
Operating Humidity Range5% to 90% RH (non-condensing)
Operating Temperature Range32°F to 120°F (0°C to 48.9°C)
Indoor Temperature Range40°F to 99°F (4.5°C to 37°C)

Summary

APPLICATION

FEATURES

Highlights the key attributes and functionalities of the thermostat.

SPECIFICATIONS

Electrical Ratings

Details the electrical requirements and ratings of the thermostat.

Interstage Differential

Explains how the thermostat manages staged heating/cooling.

PRODUCT SPECIFICATIONS AND ACCESSORIES

Optional Accessories

Lists various compatible optional accessories.

SYSTEM INSTALLATION

Finding Your Password (Date Code)

Explains how to locate the thermostat's password for setup.

INSTALLATION OPTIONS

EQUIPMENT INTERFACE MODULE AND SENSOR INSTALLATION

Sensor Mounting Locations

Guides on selecting optimal locations for temperature sensors.

THERMOSTAT LOCATION AND WALLPLATE INSTALLATION

Selecting Thermostat Location

Guidelines for choosing the best placement for the thermostat.

Installing Wallplate

Step-by-step instructions for mounting the wallplate.

THERMOSTAT WIRING AND SETUP

Wiring the Thermostat

Details on wiring the thermostat for different systems.

POWERING OPTIONAL REDLINK™ ACCESSORIES

PERFORMING INITIAL SETUP AND ACCESSORIES LINKING

Linking RedLINK Accessories

Process for connecting RedLINK accessories to the thermostat.

ADDING REDLINK ACCESSORIES AND COMPLETING SETUP

LOCATING REDLINK CONNECT BUTTONS

REDLINK GATEWAY AND TRUESTEAM SETUP

WIRELESS SENSOR AND REMOTE LINKING PROCEDURES

ACCESSING INSTALLER OPTIONS VIA PASSWORD

MAKING CHANGES TO INSTALLER SETUP

INSTALLER TESTS

Equipment Test

Detailed steps for testing heating, cooling, fan, and IAQ equipment.

Wireless Test

Steps to test the wireless communication strength and reliability.

WIRELESS SIGNAL STRENGTH TEST AND ACCESSORY MOUNTING

Mounting Optional Accessories

General guidance for mounting optional accessories.

MOUNTING INDOOR SENSORS AND REMOTES

OPERATION OVERVIEW AND DISPLAY GUIDES

Residential Display Reference

Quick guide to the residential thermostat display.

Commercial Display Reference

Quick guide to the commercial thermostat display.

SETTING BASIC THERMOSTAT FUNCTIONS

ENERGY SAVING SCHEDULES AND PROGRAMMING

OVERRIDING SCHEDULES AND VIEWING EQUIPMENT STATUS

VACATION AND HOLIDAY SCHEDULES

Setting Custom Events: Commercial Use

Customizing schedules for specific commercial events.

COMMERCIAL HOLIDAY AND EVENT SCHEDULES

COMMERCIAL OVERRIDE AND OCCUPANCY MODES

ADJUSTING HUMIDIFICATION SETTINGS

RESIDENTIAL DEHUMIDIFICATION SETTINGS

COMMERCIAL DEHUMIDIFICATION AND VENTILATION SETTINGS

SETTING PREFERENCES AND CLEANING THE THERMOSTAT SCREEN

SECURITY SETTINGS AND DEALER INFORMATION

ADVANCED FEATURES AND CONTROL ALGORITHMS

ADAPTIVE INTELLIGENT RECOVERY (RESIDENTIAL USE ONLY)

Describes the adaptive recovery feature for residential use.

SENSOR AND UNIVERSAL TERMINAL INFORMATION

Universal Outputs (U1, U2, U3)

Explains the function and use of universal output terminals.

Universal Inputs (S1–S4)

Explains the function and use of universal input terminals.

DATA LOGS AND ALERT MANAGEMENT

Alerts Log

Details on the alerts log and its contents.

DRY CONTACT ALERTS AND SETUP

STAGING CONTROL AND BACKUP HEAT DROOP

Backup Heat Droop

Explanation of the backup heat droop feature.

HEAT PUMP AND BACKUP HEAT OPERATION

Electric Backup Heat (Backup Heat Allowed to Run with Heat Pump)

Explains electric backup heat operation with heat pumps.

FOSSIL FUEL BACKUP HEAT SETUP

IAQ CONTROL AND HUMIDIFICATION SETUP

Humidification

Instructions for setting up and controlling humidification.

Window Protection

Feature to prevent frost/condensation on windows.

CONTROL HUMIDIFICATION LEVEL

RESIDENTIAL DEHUMIDIFICATION AND COOLING SYSTEM

Set up Dehumidification With Cooling System

Steps for setting up dehumidification via cooling.

DEHUMIDIFICATION USING A WHOLE HOUSE DEHUMIDIFIER

Set up Dehumidification With Whole House Dehumidifier

Steps for setting up whole house dehumidifier.

DEHUMIDIFICATION AWAY MODE AND FAN CONTROL

SET UP DEHUMIDIFICATION AWAY MODE

CONTROL DEHUMIDIFICATION LEVEL AND COMMERCIAL DEHUMIDIFICATION

DEHUMIDIFICATION USING COOLING SYSTEM AND DEHUMIDIFIER SETUP

DEHUMIDIFIER SETUP AND CONTROL SETTINGS

DEHUMIDIFICATION AWAY MODE AND CONTROL LEVEL

VENTILATION SETUP AND CONTROL METHODS

Ventilation Control Methods (ISU 1005)

Different methods for controlling ventilation.

Ventilation Fan Control (ISU 1006)

How to control the ventilation fan.

Ventilation Priority (ISU 1012)

Setting ventilation priority.

VENTILATE ON HIGH INDOOR HUMIDITY AND SETUP VENTILATION

VENTILATION PRIORITIES AND LOCKOUTS

CONTROL VENTILATION LEVEL AND OPTIONS

IAQ REMINDERS AND CUSTOMIZABLE REMINDERS

MICROSD CARD AND SOFTWARE UPDATES

Updating Thermostat Software

Steps for downloading and installing software updates.

USING THE MICROSD CARD

COMMERCIAL FEATURES AND SCHEDULE OVERRIDES

Overriding Schedules: Commercial Use

How to override schedules in commercial settings.

Setting Holiday/Event Schedules: Commercial Use

Setting holiday and event schedules for commercial use.

COMMERCIAL CUSTOM EVENTS AND HOLIDAY SCHEDULES

COMMERCIAL HOLIDAY OVERRIDE AND OCCUPANCY MODES

COMMERCIAL RAMP RATES AND REMOTE SETBACK

Set Up Remote Setback

Steps for configuring remote setback.

ECONOMIZER AND TIME OF DAY (TOD) OPERATION

Economizer

Explanation of how the economizer module works.

TIME OF DAY (TOD) AND PRE-OCCUPANCY PURGE

BATTERY REPLACEMENT FOR DEVICES

Thermostat Battery Replacement

Replacing batteries in the thermostat.

Portable Comfort Control Battery Replacement

Replacing batteries in the Portable Comfort Control.

WIRELESS INDOOR SENSOR BATTERY REPLACEMENT

OPTIONAL ACCESSORIES OVERVIEW

PORTABLE COMFORT CONTROL

Description of the Portable Comfort Control.

WIRELESS OUTDOOR SENSOR

Description of the Wireless Outdoor Sensor.

WIRELESS INDOOR SENSOR

Description of the Wireless Indoor Sensor.

REDLINK™ INTERNET GATEWAY

Description of the RedLINK Internet Gateway.

WIRELESS ENTRY/EXIT REMOTE

Description of the Wireless Entry/Exit Remote.

PORTABLE COMFORT CONTROL OPERATION

REMOTE INDOOR SENSORS OPERATION

Temperature Control

Using remote sensors for temperature control.

Humidification control

Using remote sensors for humidification control.

Dehumidification control

Using remote sensors for dehumidification control.

WIRELESS INDOOR SENSOR DETAILS

Temperature Display

How temperature is displayed from sensors.

HUMIDITY DISPLAY

SENSOR CALIBRATION INFORMATION

BACKUP CONTROL AND THERMOSTAT REPLACEMENT

REPLACING A THERMOSTAT

Steps for replacing the thermostat and its accessories.

REPLACING AN EQUIPMENT INTERFACE MODULE

Steps for replacing the EIM.

WIRING TERMINAL DESIGNATIONS

EIM WIRING DIAGRAMS

ECONOMIZER MODULE WIRING DIAGRAMS

WIRING OUTDOOR SENSOR

WIRING GUIDES FOR WIRED INDOOR SENSORS

ZONING WIRING DIAGRAMS

ZONING AND HUMIDIFICATION SETUP

Setting up Humidification Control on RedLINK VisionPRO Thermostats

Humidification setup for RedLINK thermostats in zoned systems.

ZONING AND VENTILATION SETUP

Setting up Ventilation Control on RedLINK VisionPRO Thermostats

Ventilation setup for RedLINK thermostats in zoned systems.

Setting up Dehumidification Control on RedLINK VisionPRO Thermostats

Dehumidification setup for RedLINK thermostats in zoned systems.

ZONING FAQS

TROUBLESHOOTING GUIDE

REGULATORY INFORMATION

Information regarding FCC and Industry Canada compliance.

FCC Compliance Statement (USA only)

Details of the FCC compliance statement.

Related product manuals