EasyManuals Logo

Honeywell thm5421c User Manual

Honeywell thm5421c
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
English: Page 1 Français: Page 6 Español: Página 11
3 69-1823EFS—05
Wiring guide
M23487
FACTORY INSTALLED
JUMPER BETWEEN R,
RC AND RH
1
2
3
C
R
RC
RH
COMMUNICATION
TERMINALS
COMMUNICATION LED
W1
W2
W3
Y
Y2
G
24 VAC
O/B
AUX
AUX2
Y
Y2
G
1
2
3
CONV. HP
HEAT 1 RELAY
HEAT 2 RELAY
HEAT 3 RELAY
COOL 1 RELAY
COOL 2 RELAY
FAN RELAY
WIRE TO TERMINALS ON THERMOSTAT.1
1
Typical hookup of conventional system with up to three-stage heat and two-stage cool with one
transformer (3H/2C, 2H/2C, 2H/1C, 1H/2C, 1H/1C, 1H, 2H, 3H, 1C, 2C conventional).
M23490
1
2
3
C
R
RC
RH
24 VAC
H1
U
M2
D1
H
M2
V1
N
T2
OR
POWERED
HUMIDIFIER
Typical hookup of powered humidifier.
M23488
FACTORY INSTALLED
JUMPER BETWEEN R,
RC AND RH
1
2
3
C
R
RC
RH
COMMUNICATION
TERMINALS
COMMUNICATION LED
W1
W2
W3
Y
Y2
G
24 VAC
O/B
AUX
AUX2
Y
Y2
G
1
2
3
CONV. HP
CHANGEOVER
AUX 1 (HEAT 3)
AUX 2 (HEAT 4)
COMP 1
COMP 2
FAN RELAY
WIRE TO TERMINALS ON THERMOSTAT.
1
1
Typical hookup of heat pump system with up to four-stage heat and two-stage cool with one
transformer (4H/2C, 3H/2C, 2H/2C, 2H/1C, 1H/1C heat pump systems).
Wiring guideequipment
With power supply Without power supply
M23489
FIELD INSTALLED
JUMPER BETWEEN
R AND HUM 1
1
2
3
C
R
RC
RH
24 VAC
H1
U
M2
D1
H
M2
V1
N
T2
OR
NON-POWERED
HUMIDIFIER
Typical hookup of non-powered humidifier.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell thm5421c and is the answer not in the manual?

Honeywell thm5421c Specifications

General IconGeneral
BrandHoneywell
Modelthm5421c
CategoryThermostat
LanguageEnglish