Honeywell THP9045A - 5 c Two-Stage Heat, Two-Stage Cooling Wiring

Honeywell THP9045A
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
5c Wire two-stage heat, two-stage cooling
1. Do not disconnect the W2 or Y2 wires from your heating/cooling system.
2. Disconnect the R wire from your heating/cooling system’s terminal block.
3. Connect the R wire to the Rc terminal on the THERMOSTAT end of the wire saver.
4. Disconnect the W wire from the heating/cooling system; connect it to W on the
THERMOSTAT end of the wire saver.
5. Disconnect the G wire; connect it to K on the THERMOSTAT end of the wire saver.
6. Disconnect the Y wire; connect it to C on the THERMOSTAT end of the wire saver.
7. Connect stripped ends of the included wire bundle to the terminals labeled EQUIPMENT
on the wire saver in this color order:
a. Connect red to Rc
b. Connect yellow to Y
c. Connect green to G
d. Connect blue to C
e. Connect white to W
8. Connect the other set of stripped ends to the terminals on your heating/cooling system
following the same color order.