EasyManua.ls Logo

Honeywell TrueDRY DR120 - Wiring Diagrams (Continued); TrueIAQ Digital Control Wiring; VisionPRO IAQ Control Wiring

Honeywell TrueDRY DR120
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Wiring (continued)
Follow this diagram if using TrueDRY
DR90/DR120 with a powered dehumidistat
such as TrueIAQ (DG115EZIQ).
HVAC
THERMOSTAT
GYWRRc
M29842A
IF A THERMOSTAT OTHER THAN A TH5110, TH5220, TH5320, TH6110, TH6220, TH6320,
TH8110, TH8320, OR TH8321 IS USED, A RELAY MAY BE REQUIRED TO ISOLATE THE G WIRE.
PROGRAM ISU SETTING 60 TO Ø TO FORCE SYSTEM FAN ON WITH DEHUMIDIFICATION CALL.
C
68
40
55
1215
:
76
%
%
In
Out
PM
R
C
W
Y
G
R
C
SENSOR
SENSOR
SWITCH
W
G
VENT
VENT
DEHUM
DEHUM
HUM
HUM
OUTDOOR
SENSOR
(PROVIDED)
EARD-6
Tr ueIAQ
1
1
2
2
TrueDRY
DHUM
+
+
R
FAN
C
FLOAT
TrueDryDR90/DR120DehumidicationSystem69-2690EFS—04
10
Follow this diagram if using TrueDRY
DR90/DR120 with a VisionPRO IAQ.
M29843A
FURNACE
FAN BOARD
G
C
CONV.HP
1
2
3
C
R
RC
RH
W1
W2
W3
Y
Y2
G
O/B
AUX
AUX2
Y
Y2
G
H1
U
M2
D1
H
M2
V1
N
T2
HEAT 1 RELAY
HEAT 2 RELAY
HEAT 3 RELAY
COOL 1 RELAY
COOL 2 RELAY
FAN RELAY
VISIONPRO IAQ
D-1
R-2
C-3
FLOAT
FLOAT
DHUM
R
FAN
C
OR
EARD-6
TrueDRY
+
+

Related product manuals