EasyManua.ls Logo

Honeywell TrueSTEAM - Welcome to TrueSTEAM; Welcome

Honeywell TrueSTEAM
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TrueSTEAM Humidification System
3 69-2285EFS—03
CONTRACTORS: IMPORTANT INSTALLATION REQUIREMENTS
Failuretocomplywillresultinvoidedwarranty,improperinstallation,andservicecallbacks.
M28711
DUCT MOUNT INSTALLATION
Choose a location that has access to a:
• Drainwithahigh-temperaturewater
rating. Refer to local plumbing codes
to ensure proper draining.
• Coldwatersupplylinemustbeused.
• Electricalcircuitratedtoyour
humidifier.
• Verticalsurfacewithadequate
clearances.
Model
Required Minimum
Circuit Capacity
HM506 7 Amps
HM509 10 Amps
HM512 12 Amps
M24745
Install duct nozzle.
M24746A
Ensure o-ring gasket
is properly seated in
the groove.
Slide foam gasket
down over nozzle.
M24894
Insert nozzle and twist clock-
wise to ensure tight seal of
nozzle to TrueSTEAM.
11.5 in.
19 in.