EasyManua.ls Logo

Honeywell V-PLEX 5192SD User Manual

Honeywell V-PLEX 5192SD
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
The Honeywell 5192 Series low profile, addressable V-Plex
smoke detectors deliver state-of-the-art features and
benefits in a cost-effective package. These detectors are
designed to provide open area coverage and are
compatible with Honeywell’s VISTA controls supporting
V-Plex technology.
An LED on the detector will blink periodically during normal
conditions, remain on steady during alarm and cease to
pulse if the chamber is out of acceptable sensitivity range.
An extremely powerful feature available within the 5192
Series is the Automatic Maintenance Alert/Reporting
capability – a feature normally found in today’s high end
analog addressable systems. The detectors continually
monitor their own sensitivity levels in addition to the basic
normal and alarm conditions. These HIGH and LOW
SENSITIVITY signals are communicated back to the
control, via the V-Plex addressable loop, to indicate locally
and at the central station that the detector may not be able
to detect smoke or may false alarm. This feature works
with VISTA-32FB, 128BP, 128FBP, 250BP, 250FBP, 40,
50P, 100-24 and FAP FA1600C, FA1660C and FA1700C.
More important is the cost saving associated with
Automatic Maintenance Reporting. The feature is an
approved alternate to NFPA 72 field sensitivity calibration
testing that require external test meters. This eliminates the
need to schedule inspections to determine detector
sensitivity/viability. Another important benefit of these V-Plex
(addressable) smoke detectors is their ability to operate on
existing wiring.
There is no need to run special twisted pair, data grade or
shielded wires, providing you with the right choice for all
your retrofit applications. That equates to cost savings in
time and materials!
• Low profile design
• V-Plex addressable loop device
• Automatic maintenance reporting
• Available with integral heat sensor
• Simple 2 wire installation
• DIP switch or serial number
programmable
• Lines on existing or
conventional wiring
FEATURES
The 5192 Series smoke detectors are designed to provide open area coverage and are well suited for most fire detection
applications. These smoke detectors are compatible with all Honeywell VISTA Fire and Burglary controls that support V-Plex
addressable loop technology. These agency listed alarm initiating devices support most commercial and residential applications. They are
suited for use in museums, hospitals, day care centers, retail stores, strip malls, schools, libraries, fast food chains, medical or
professional office suites and in factory and warehouse environments.
APPLICATIONS
5192SD/5192SDT
V-PLEX
®
SMOKE DETECTOR
Question and Answer IconNeed help?

Do you have a question about the Honeywell V-PLEX 5192SD and is the answer not in the manual?

Honeywell V-PLEX 5192SD Specifications

General IconGeneral
Sensor TechnologyPhotoelectric
Interconnect CapabilityNo
Hush FeatureYes
LED IndicatorYes
ComplianceUL 268
Alarm Volume85 dB at 10 feet
Operating Temperature32°F to 100°F (0° to 38°C)
Humidity Range0% to 95% RH, non-condensing
SounderYes
Alarm Sound Level85 dB at 10 ft

Summary

Product Features

Product Applications

Product Specifications

Installation & Wiring

Details on mounting bracket, terminal block, wiring, and compliance with UL/NFPA standards for installation.

Compatibility & Reporting

Lists compatible control panels for automatic maintenance alert/reporting and V-Plex polling loop compatibility.

Electrical & Environmental Specs

Details system voltage, current, installation temperature, and humidity ranges.

Mechanical & Agency Listings

Provides dimensions, weight, and lists UL/residential requirements met by the detector.

Product Ordering Information

Related product manuals