1 69-0329—4
V8205, VR8205 Direct Ignition
Combination Gas Controls
Installation Instructions for the Trained Service Technician.
G. S. • Rev. 12-93 • ©Honeywell Inc. 1993 • Form Number 69-0329—4
TABLE 1—DIRECT IGNITION COMBINATION GAS CONTROL MODELS.
TABLE 2—MODEL NUMBER
SUFFIX LETTER DESIGNATION.
TABLE 3—FLANGE PART NUMBERS.
NOTE: Flange Kits include one flange with attached O-ring
and four mounting screws. TRADELINE
®
kits include a
9/64 in. hex wrench, as noted.
APPROVALS:
American Gas Association design certificate: L2025006.
Canadian Gas Association design certificate: L2025006.
Australian Gas Association design certificate: 4214.
Approved for Delta C applications.
Installation
WHEN INSTALLING THIS PRODUCT…
1. Read these instructions carefully. Failure to follow
them could damage the product or cause a hazardous condi-
tion.
2. Check the ratings given in the instructions and on the
product to make sure the product is suitable for your appli-
cation.
3. Installer must be a trained, experienced service tech-
nician.
4. After installation is complete, check out product op-
eration as provided in these instructions.
Part No.
Inlet/Outlet
Pipe Size
Flange
Type
Less Hex
Wrench
With Hex
Wrench
3/8 in. NPT Straight 393690-1 393690-11
Elbow 393690-2 393690-12
1/2 in. NPT Straight 393690-6 393690-16
Elbow 393690-3 393690-13
3/4 in. NPT Straight 393690-4 393690-14
Elbow 393690-5 393690-15
Model No.
Suffix
Letter
Ambient
Temperature
Range
Regulator
Type
A0° F to 175° F Standard
[-18° C to 79° C]
C Step-opening
H Slow-opening
K -40° F to 175° F
[-40° C to 79° C]
M Standard
P Step-opening
Model
Voltage/
Frequency
Number of
Automatic Operators
Gas Control
Knob Positions Current Draw
V8205 24V/60 Hz One OFF-ON 0.30A
VR8205 24V/60 Hz Two OFF-ON 0.5A
These direct ignition gas controls are used in gas-fired
appliances with up to 200 cfh capacity on natural gas. They
include safety shutoff, a manual valve, one or two auto-
matic operators and a pilot adjustment. See Table 1 for
model differences and Table 2 for temperature ranges and
regulator types.
BODY PATTERN: Straight through with 1/2 in. inlet
and 1/2 in. outlet.
PIPE ADAPTERS: Angle and straight adapters available
for 3/8, 1/2 and 3/4 in. pipe. See Table 3.
These gas controls are factory-set for natural (and manu-
factured) gas or LP gas. Do not attempt to use a control set
for natural (manufactured) gas on LP gas, or a control set
for LP on natural (manufactured) gas.
Controls with standard or slow opening regulators can be
converted from one gas to the other with a conversion kit
(ordered separately). Order part no. 393691 to convert from
natural (manufactured) to LP gas; order part no. 394588 to
convert from LP to natural (manufactured) gas. Controls
with step opening regulators cannot be converted.
Application