Partitions | 8 |
---|---|
User Codes | 150 |
Keypads Supported | Up to 16 |
Zones | 128 |
Battery Backup | 12VDC, 7AH |
Operating Temperature | 32°F to 120°F (0°C to 49°C) |
Relative Humidity | 5% to 95% non-condensing |
Compliance | UL, FCC |
Guidelines and specific features required for UL864 Commercial Fire compliance.
Specific programming field settings and options required for UL864 compliance.
Step-by-step guide for configuring a partitioned system.
Instructions for physically mounting the control panel cabinet.
Specific wiring and installation requirements for commercial fire installations.
Steps for correctly mounting the main circuit board within the cabinet.
Connecting the main and backup dialers to telephone lines.
Instructions for connecting burglary and panic devices to hardwired zones.
Guide for installing V-Plex devices on the polling loop.
Information on expanding the system with wireless zones and receivers.
Step-by-step guide for installing the 5881ENHC/5883 RF receivers.
Guidelines for installing output devices like relay modules.
Procedure for installing 4204 and 4204CF relay modules.
Guide for installing a remote keyswitch for arming/disarming and silencing.
Connecting IP or GSM communicators to the ECP bus.
Procedure for installing the communications device.
Instructions for connecting the 18VAC transformer for panel power.
Worksheets for calculating total system power supply load requirements.
Guide for calculating and selecting the correct standby battery capacity.
Procedures for entering and exiting the installer programming mode.
Explanation of how to navigate and program data fields.
How to program global system settings that apply to all partitions.
Overview of the interactive #93 Menu Mode for programming system functions.
List of main menu options and their programming functions.
Detailed definitions of each zone response type and its function.
Definitions of input types for zones, such as hardwired, RF, or polling loop.
Steps for programming the communicator's reporting and signaling options.
Instructions for entering data into programming fields.
Configures the delay time for entry into a partition.
Configures the delay time for exiting a partition.
Configures a secondary delay for entry into a partition.
Configures a secondary delay for exiting a partition.
Enters the primary central station phone number for alarm transmission.
Enters the secondary phone number for backup or split reporting.
Selects the reporting format for the primary telephone number.
Selects the reporting format for the secondary telephone number.
Configures expanded reporting for the primary phone number.
Configures expanded reporting for the secondary phone number.
Sets the time window during which non-fire alarm reports are suppressed.
Sets delay time between arming window end and auto-arm warning.
Sets the duration of keypad warning before auto-arming.
Sets delay time between disarming window end and auto-disarming.
Sets the maximum number of attempts the dialer makes to transmit.
Enables or disables the main and backup dialers for system reporting.
Selects the condition that triggers the auxiliary relay.
Automates arming of partitions at the end of a closing time window.
Automates disarming of partitions at the end of an opening time window.
Defines start and stop times for scheduling events.
Guide to using the #80 menu mode for programming schedules.
Programming the system's 20 time windows with start and stop times.
Assigning daily open/close schedules to each partition.
Programming holiday schedules into the system.
Schedules to automatically activate outputs or system functions at set times.
List of action codes used for programming timed events.
Defines when a timed event action occurs relative to a time window.
Programming specific timed events for outputs and system functions.
Limits user access codes to specific time periods and days.
Programming access schedules into the system.
Overrides regular schedules for up to one week.
Programming temporary schedules for partitions.
Allows end users to control output devices via timers.
Requirements for downloading via standard telephone lines.
Methods for downloading via IP or GSM communicators.
Allows remote download without operator presence.
Steps to establish an on-line connection between computer and panel.
Downloading without modem/telephone line using 4100SM Serial Module.
Step-by-step instructions for setting the system's real-time clock.
Explanation of authority levels and how they grant system access.
Details on the installer's code, its functions, and limitations.
Capabilities and functions of Master user codes.
Capabilities and functions of Manager user codes.
Capabilities and functions of Operator user codes.
Sends a silent alarm to monitoring station when forced to disarm.
How users can be given access to multiple partitions.
Procedure for adding new Master, Manager, or Operator user codes.
Procedure for changing existing Master, Manager, or Operator codes.
Procedure for deleting Master, Manager, or Operator user codes.
How the system performs battery tests and indicates low battery conditions.
Programming and performing dialer tests for central station communication.
Activates notification appliance circuits for fire drill testing.
Checks fire zone operation without triggering alarms.
Tests burglary zone operation by faulting zones.
Procedure for performing burglary system tests while armed.
Methods for testing wireless transmitters' programming and enrollment.
Explanation of various trouble messages and their causes.
Details common zone and system trouble conditions.
Guidance for installers on properly training users on system functions.
Requirements for UL2050 compliance in commercial burglary installations.
Requirements for UL864/NFPA local fire installations.
Requirements for UL864/NFPA central and remote station fire systems.
Specific requirements for all UL Commercial Burglary installations.
Guidelines for UL609 local mercantile installations.
Instructions for UL365 police station connected burglar alarm installations.
Guidelines for UL1610 central station burglary alarm installations.
Commands for initiating downloads and entering programming modes.
Commands for performing burglary walk-tests, fire drills, and transmitter tests.
Physical and electrical specifications for the VISTA-128FBPN control panel.
Table listing Contact ID codes and their definitions for event reporting.