EasyManua.ls Logo

Honeywell ADEMCO VISTA-120 User Manual

Honeywell ADEMCO VISTA-120
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
N5943-8V4 7/04 Rev A
A
AA
A
A
AA
A
D
DD
D
D
DD
D
E
EE
E
E
EE
E
M
MM
M
M
MM
M
C
CC
C
C
CC
C
O
OO
O
O
OO
O
V
VV
V
V
VV
V
I
II
I
I
II
I
S
SS
S
S
SS
S
T
TT
T
T
TT
T
A
AA
A
A
AA
A
-
--
-
-
--
-
1
11
1
1
11
1
2
22
2
2
22
2
0
00
0
0
00
0
Security System
Security SystemSecurity System
Security System
With Scheduling
With SchedulingWith Scheduling
With Scheduling
User Guide

Table of Contents

Other manuals for Honeywell ADEMCO VISTA-120

Question and Answer IconNeed help?

Do you have a question about the Honeywell ADEMCO VISTA-120 and is the answer not in the manual?

Honeywell ADEMCO VISTA-120 Specifications

General IconGeneral
BrandHoneywell
ModelADEMCO VISTA-120
CategorySecurity System
LanguageEnglish

Summary

System Overview

General System Introduction

Provides a general overview of the Honeywell security system components and purpose.

Partitioned System Functionality

Explains how a single security system can be shared among multiple users.

Panel Linking and Zone Assignments

Panel Linking for Multi-Building Environments

Describes networking up to eight VISTA-120 control panels for central management.

Zone Assignments and Descriptions

Explains how sensing devices are assigned to numbered zones within the system.

Fire Protection System Features

Details the system's fire protection capabilities and how alarms are triggered.

Burglary Protection, Alarms, and Memory

Burglary Protection Modes and Features

Outlines the four modes of burglary protection and system arming features.

Alarm Notification and Response

Explains how the system responds to alarms, including sound and display notifications.

Memory of Alarm Logging

Describes how the system records and displays alarm events until cleared.

Advanced System Features

Speed Key (Macros) for Automation

Explains the feature for storing and executing strings of up to 32 keystrokes.

Using System Schedules for Automation

Covers automatic arming/disarming and device activation based on programmed schedules.

Device Timer Programming

Details the system's 20 timers for controlling devices like lights or appliances.

Accessing Other Partitions via GOTO

Describes how to use the GOTO command to operate functions in different system partitions.

Keypad and Remote Access Features

Master Keypad Operation and Status

Explains the function of a Master keypad displaying status for all partitions.

Self-Help Feature for User Instructions

Describes how to view abbreviated user instructions on the alpha keypad display.

Remote Phone Access and Voice Response

Details remote system access and control via telephone using specific modules.

About The Keypads

Keypad General Features and Alerts

Covers keypad display, sounders, and programmable backlighting.

Keypad Functions and Indicators

Alpha Display Window Functionality

Describes the 2-line, 32-character LCD for displaying system information.

Arming Keys (OFF, AWAY, STAY, MAXIMUM, TEST, BYPASS, INSTANT, CODE)

Details the functions of the primary arming and system control keys.

Additional Keypad Functions

Chime, Ready, and Quick Arm Functions

Explains chime mode, checking readiness, and quick arming features.

Numeric Keys and System Indicators

Covers numeric key usage, LED indicators, speaker, and CPU status.

Function Keys for Macros and Panic

Describes the use of function keys for Speedkey macros or panic functions.

Entry and Exit Delays

General Information on Entry/Exit Delays

Explains installer-programmed exit and entry delays for arming and disarming.

Security Codes and Authority Levels

General Information on Codes and Levels

Discusses user assignments, authority levels, and security codes.

Duress Code and Quick Arming

Explains the use of a duress code for silent notification and quick arming.

Authority Level Definitions and Restrictions

Code and Authority Level Management

Rules for Code and Authority Level Changes

Outlines rules for adding, changing, and deleting user codes and authority levels.

Exiting User Edit Mode Procedures

Describes how to exit user edit modes by pressing keys or time-out.

Adding a New User to the System

Modifying and Deleting User Codes

Changing a User's Security Code

Details the process for modifying an existing user's security code.

Deleting a User from the System

Explains how to remove a user's code and associated information from the system.

Accessing Other Partitions

GOTO Command for Partition Access

Explains how to use the GOTO command to access and control other partitions.

Global Arming Functionality Explained

Describes the Global Arming option for arming/disarming multiple partitions simultaneously.

Master Keypad Partition Status Display

Common Area Operation Logic and Interaction

User Codes and Common Area Interaction

Accessing Other Panels

Single-Partition Single-Panel Mode Access

Describes accessing and controlling a single partition on a linked panel.

Multi-Partition and Multi-Panel Access

Multi-Partition Multi-Panel Mode Access

Explains accessing and controlling multiple partitions across linked panels.

Multi-Panel View Mode Access

Priority of Panel Displays in Multi-Modes

Checking for Open Zones

Using the READY Key for Zone Status Checks

Explains how to use the READY key to check for faulted zones before arming.

Bypassing Protection Zones

Using the BYPASS Key for Zone Bypassing

Details the procedure for bypassing specific zones from system monitoring.

Advanced Bypassing Techniques

Quick Bypass Feature for Open Zones

Describes bypassing all open zones simultaneously without individual entry.

Displaying Previously Bypassed Zones

Explains how to view zones that have been previously bypassed.

Arming Perimeter Only (Stay Mode)

Using the STAY Key for Perimeter Arming

Details arming the system in STAY mode for perimeter protection with entry delay.

Arming Perimeter Only (Instant Mode)

Using the INSTANT Key for Perimeter Arming

Explains arming in INSTANT mode without entry delay for perimeter security.

Arming All Protection (Away Mode)

Using the AWAY Key for Full Arming

Details arming the system in AWAY mode for full interior and perimeter protection.

Arming All Protection (Maximum Mode)

Using the MAXIMUM Key for Full Arming

Explains arming in MAXIMUM mode without entry delay for vacant premises.

Disarming and Silencing Alarms

Using the OFF Key for Disarming

Details the procedure for disarming the system and silencing alarms.

Memory of Alarm Display and Clearing

Explains how to view and clear the memory of past alarm events.

Using The Keyswitch

Keyswitch General Information and Indicators

Describes the keyswitch and its indicator lights for system status.

Keyswitch Arming Procedures

Explains how to arm the system using the keyswitch in AWAY or STAY modes.

Keyswitch Disarming Procedure

Details how to disarm the system using the keyswitch.

Chime Mode Operation

Using the CHIME Key for Mode Control

Explains how to activate and deactivate the CHIME mode for door/window alerts.

Viewing Alarm Company Messages

General Information on Message Viewing

Describes how users receive and view messages from monitoring agencies or installers.

Panic Key Functions

Using Panic Keys for Emergency Activation

Explains how to manually activate panic functions using key combinations.

Active Panic Function Types Explained

Lists and describes Silent, Audible, Personal, and Fire emergency panic functions.

Speed Key (Macros) Configuration

General Information on Macros

Introduces macros as strings of commands up to 32 keystrokes for automation.

Defining a Speed Key Macro Sequence

Provides instructions on how to program new Speed Key sequences.

Executing a Speed Key Sequence

Access Door Control System

General Information on Access Door Control

Explains how the system can control locked access doors via keypad commands.

Using #70 Relay Menu Mode

General Information on Relay Control

Describes controlling lights and devices using the #70 command from keypads or phones.

System Schedules Management

Delaying the Closing Time Feature

Explains how authorized users can manually delay automatic system arming.

Programming Temporary Schedules

Programming Device Timers

General Information on Device Timers

Explains the system's 20 timers for controlling up to 96 devices.

Using #77 Instant Activation Mode

Relay Commands via #77 Mode

Lists action codes for activating relays and relay groups using #77 mode.

Arm/Disarm Commands via #77 Mode

Details action codes for automatic arming and disarming functions via #77 mode.

Advanced #77 Instant Activation Commands

Bypass Commands via #77 Mode

Lists action codes for auto-bypassing zones using #77 mode.

Open/Close Time Period Commands via #77

Describes commands for enabling opening/closing time periods via #77 mode.

Access Control Commands via #77 Mode

Lists action codes for managing access points and groups using #77 mode.

Additional #77 Instant Activation Commands

Additional Commands via #77 Mode

Covers additional commands for access control groups and triggers via #77 mode.

Event Log Procedures

General Information on Event Logs

Explains the system's ability to record and store up to 512 events.

Displaying Event Log Data

Details how to select display modes (RECENT/COMPLETE) and partitions for viewing logs.

Event Log Categories and Descriptions

System Testing Procedures

Using the TEST Key for System Checks

Explains how to enter Test mode to check system operation and protection points.

Conducting System Testing Steps

Provides steps for testing doors, windows, motion detectors, and smoke detectors.

Fire Alarm System Operation

In Case of Fire Alarm Emergency

Outlines immediate actions to take if a fire is detected or suspected.

Silencing a Fire Alarm Event

Details the steps to silence a fire alarm and clear the display after the event.

Trouble Conditions and Displays

Typical Trouble Display Messages

Explains common trouble messages like CHECK, TRBL, and CALL SERVICE.

Power Failure and System Status Messages

System Maintenance and Care

General System Care and Cleaning

Provides general advice on keeping the security system components clean and functional.

Replacing Wireless Sensor Batteries

Explains how to identify and replace batteries in wireless sensors and keypads.

Low Battery Warnings and Routine Care

Silencing Low Battery Warning Tones

Details how to silence low battery warning beeps and clear the display.

Routine Care and Cleaning Recommendations

Offers basic cleaning instructions for keypads and sensors.

Quick Guide to System Functions

Zone Status, Descriptors, and System Arming

Covers checking zones, displaying descriptors, and system arming basics.

Bypass, Chime, Self-Help, and Testing

Outlines bypassing zones, chime mode, self-help, and system testing.

User Management and Partition Access

Summarizes user management, code changes, and accessing partitions.

User Deletion and Panel Linking

User Deletion and Access Control

Details user deletion and activating access relays or points.

Panel Linking Procedures Overview

Summarizes procedures for single-panel, multi-panel, and multi-view panel linking.

Summary of Audible Notifications

One Year Limited Warranty

Related product manuals