43-TV-33-71 iss.2 GLO Jan 21 UK 3
To remove the Front surround assembly four self tapping screws must be removed. See Fig 3
Once these have been removed the front surround assembly can be carefully drawn forward. Disconnect the speaker
cable from the mother board. Disconnect the display cable, inverter cable and touch screen cable from the processor
board. Take care not to pull on the cable, only on the connector body.
The display cable is unplugged by gently pulling up the top part of the connector until the cable is unclamped and can
easily be pulled free.
Take the front surround assembly and lay it flat, ensuring that it is on a surface where it will not get scratched or
damaged.