If you have identied a fault in the table above that calls for the Room Unit to be
rebound to the wireless relay- please follow these simple steps to re-establish
contact.
STAGE 1 Press and
hold for 15 sec
The red light will ash on for
0.1 sec and be o for 0.9 sec
STAGE 2 Press and
hold for 5 sec
The red light will ash on for 0.5
sec and be o for 0.5 sec
Please follow the steps below for the relevant thermostat
NB – Always keep the thermostat and wireless relay unit at least 1metre apart
during the re-binding process.
1) It is important to delete any previous binding from the relay memory before
starting. On the BDR91 Wireless relay unit, press and hold the button wait
until the red light starts to ash – continue holding until it changes to a fast
ash then release.
2) Press and hold the button again for 5 seconds (until the red LED blinks
slowly). Then release and go to the next step.
CMT900 & CMT700 range of Wireless Programmable Room Thermostats
1) Move the room thermostat slider to the OFF (CMT900) position or press
the o button (CMT700) and press the and buttons together
along with the button. The unit will display “InSt” and ‘CONTROL
BINDING’.
2) Press the green button to send the binding signal out to the Relay Box.
The red LED on the relay is switched o to conrm successful binding
operation. If the red LED still ashes push the button again until binding is
successful.
3) Return the slider to AUTO (CMT900) or press the AUTO button (CMT700)
1
2
CMT900
CMT700
OK
Re-binding of wireless products
Re-binding of wireless products