Re-binding of wireless products
DT92E Wireless Digital Room Thermostat
1) Press and hold the power button for 2 seconds to put the unit into
standby
2) Press the up and down arrows together for 3 seconds – it should say INst
3) Press the down arrow – it should say COnt
4) Press the up arrow three times – it should say CLr
5) Press the power button once to clear any previous binding data
6) Press the up arrow – it should say Cont
7) Press the power button to send the binding signal to the wireless relay
8) The screen will return to normal and the red light will disappear from the
relay
9) Press the power button for 5s and the screen will return to normal
Y6630D Wireless Room Thermostat
1) The Y6630D uses the HC60 relay unit, but clearing the memory and putting
the unit into listening mode is the same as the BDR91 on the front page
2) Take the front cover o of the thermostat
3) Press the “send” button
4) The red light on the receiver should disappear if it has been successful
Y87RF Wireless Room Thermostat
1) Touch and hold on the left touch zone for approximately 10 seconds
2) The screen for binding the Boiler Relay is now displayed
3) When the symbol ‘bo’ is ashing, briey touch the left touch zone to send
the binding signal, at which point the symbol will ash several times.
4) If binding has been successful the number indicates the signal strength
(1 = min to 5 = max).
5) If binding fails, appears on screen. Please try again.
6) The red LED on the Boiler Relay will turn o when binding has been
successful.
Red
Light
Send
Button