PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION
Vacuum won’t
run
1. Power cord not firmly plugged
into outlet.
1. Plug unit in firmly.
2. Blown fuse or tripped breaker. 2. Check fuse or breaker in home. Replace
fuse/reset breaker in home.
4. Thermal Protector activated. 4. Unplug and allow vacuum to cool for 30min.
(This willl reset the thermal protector)
System Check
Indicator has
turned red
or
Vacuum won’t
pick up
or
Low suction
1. Rinsable Filter and/ or HEPA
Filter is dirty.
1. Clean Rinsable Filter and/ or HEPA Filter -
Pg.9
2. Dirt Cup full and/ or clogged. 2. Empty Dirt Cup - Pg.8.
3. Broken or worn Belt. 3. Replace Belt - Pg.12.
4. Brushroll and/ or Hose
clogged.
4. Check Hose - Pg.11. Check Brushroll - Pg.10.
5. Carpet height setting is
incorrect.
5. Set Carpet Height Adjustment to appropriate
setting for carpet being cleaned - Pg.7.
Dust escaping
from vacuum
1. Dirt Cup full. 1. Empty Dirt Cup - Pg. 8.
2. Dirt Cup not installed correctly. 2. Review Dirt Cup removal & replacement -
Pg. 8.
3. Hose not installed correctly. 3. Review Hose installation - Pg. 7.
4. Rinsable and/or HEPA Filter
not installed completely.
4. Review Filter Removal and Cleaning.
Powered Hand
Tool brushroll
won’t turn
1. Too much pressure being
applied to tool.
1. Continue using tool applying light pressure.
2. Blockage. 2. Remove blockage - Pg. 11
3. Low vacuum suction. 3. Check items under “Vacuum won’t pick or
Low suction.”
Smoky/burning
smell detected
1. Belt broken or stretched. 1. Replace brushroll belt - Pg. 12.
2. Brushroll is clogged. 2. Clear/ remove debris from brushroll - Pg. 10.
5. TROUBLESHOOTING
If a minor problem occurs, it usually can be solved quite easily when the cause is found by using the
checklist below.
Any other servicing should be done by an authorized service representative.
WARNING
! !
To reduce risk of personal injury - unplug vacuum before servicing.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hoover Windtunnel UH70120 and is the answer not in the manual?

Hoover Windtunnel UH70120 Specifications

General IconGeneral
TypeUpright
BaglessYes
Filter TypeHEPA
Height AdjustmentYes
Power SourceCorded Electric
Voltage120V
Amps12 A
Hose Length8 ft
On-Board ToolsYes
Washable FilterYes
Cord Length25 ft
Cleaning Path13.5 inches
Dust Capacity1.5 liters