8๎
๎
Field๎Installation๎
Field๎Installation๎
Safety๎Information๎and๎Guidelines๎
Only๎qualified๎service๎technicians๎should๎
attempt๎to๎install,๎service,๎or๎maintain๎the๎Ice๎
Flaker.๎
Make๎sure๎all๎power๎sources๎are๎disconnected๎
before๎any๎service๎work๎is๎done๎to๎the๎Ice๎
Flaker.๎
All๎field๎wiring๎must๎conform๎to๎the๎
requirements๎of๎the๎equipment๎and๎all๎
applicable๎local๎codes๎and๎national๎codes.๎
Always
๎refer๎to๎the๎Condensing๎Unit๎
manufacturerโs๎installation๎manual๎for๎further๎
specification๎and๎guidance.๎
Inspection๎
Upon๎receipt,๎check๎all๎items๎against๎the๎bill๎of๎
lading๎to๎make๎sure๎all๎crates๎and๎cartons๎are๎
accounted๎for.๎
Any๎shortage๎or๎damages๎should๎be๎reported๎to๎
the๎delivering๎carrier.๎๎Damaged๎material๎
becomes๎the๎delivering๎carrierโs๎responsibility๎
and๎should๎not๎be๎returned๎to๎the๎
manufacturer๎unless๎prior๎approval๎is๎given.
๎
Take๎care๎not๎to๎damage๎equipment๎when๎
uncrating.๎
Condensing๎Unit๎Rigging๎and๎
Mounting๎
Rigging๎holes๎are๎provided๎on๎all๎units.๎๎Caution๎
should๎be๎exercised๎when๎moving๎these๎units.๎๎
To๎prevent๎damage๎to๎the๎unit๎housing๎during๎
rigging,๎cables๎or๎chains๎used๎must๎be๎held๎
apart๎by๎spacer๎bars.๎๎The๎mounting๎platform๎or๎
base๎should๎be๎level๎and๎located๎so๎as๎to๎permit๎
free๎access
๎of๎supply๎air.๎
Ground๎Mounting๎
Concrete๎slab๎raised๎six๎inches๎above๎ground๎
level๎provides๎a๎suitable๎base.๎๎Raising๎the๎base๎
above๎ground๎level๎provides๎some๎protection๎
from๎ground๎water๎and๎windโblown๎matter.๎๎
Before๎tightening๎mountin g๎bolts,๎recheck๎level๎
of๎unit.๎๎The๎unit๎should๎in๎all๎cases๎be๎located๎
with๎
a๎clear๎space๎in๎all๎directions๎that๎is๎at๎a๎
minimum,๎equal๎to๎the๎height๎of๎the๎unit๎above๎
the๎mounting๎surface.๎๎A๎condensing๎unit๎
mounted๎in๎a๎corner๎formed๎by๎two๎walls,๎may๎
result๎in๎discharge๎air๎recirculation๎with๎
resulting๎loss๎of๎capacity.๎
Roof๎Mounting๎
Due๎to๎the๎weight๎of
๎the๎units,๎a๎structural๎
analysis๎by๎a๎qualified๎engineer๎may๎be๎required๎
before๎mounting.๎๎Roof๎mounted๎units๎should๎
be๎installed๎level๎on๎steel๎channels๎or๎an๎Iโbeam๎
frame๎capable๎of๎supporting๎the๎weight๎of๎the๎
unit.๎๎
Access๎
Provide๎adequate๎space๎at๎the๎compressor๎end๎
of๎the๎unit๎for๎servicing.๎๎
Provide๎adequate๎
space๎on๎the๎connection๎side๎to๎permit๎service๎
of๎components.๎
๎
๎