Problem
Possible
Causes Remedy
Appliance
not used
for a long
period of
time.
Contact Hozelock
Consumer Services /
Service Agent.
Problems
with TSS
device.
Contact Hozelock
Consumer Services /
Service Agent.
Motor fails
to start.
No
electrical
power.
Check that the plug is
firmly in the socket and
that the mains voltage
supply is present.
Problem
with TSS
device.
Contact Hozelock
Consumer Services /
Service Agent.
Water
leakage.
Seals worn. Contact Hozelock
Consumer Services /
Service Agent.
Appliance
noisy.
Water too
hot.
Reduce temperature (see
technical data).
Oil leakage. Seals worn. Contact Hozelock
Consumer Services /
Service Agent.
Motor
starts even
with gun
trigger is
released.
Nozzle
clogged.
Clean nozzle (fig 26).
High
pressure
system
or pump
hydraulic
circuit not
Watertight.
Contact Hozelock
Consumer Services /
Service Agent.
No water
delivery
when gun
trigger is
depressed
(with
supply hose
connected).
Nozzle
clogged.
Clean nozzle (fig 26).
If the motor starts and does not restart during
operation, wait 2-3 minutes before repeating the start-
up procedure (overload cut-out has been tripped).
If the problem recurs more than once, call your
Hozelock Consumer Services / Authorised Service
Agent.
Technical Data*
Technical Data Unit 7920
Output L/min 5.5
Maximum Output L/in 7.3
Pressure MPa 9.5
Maximum Pressure MPa 14
Power Kw 1.7
Tº input (max.) ºC 50
Maximum input pressure MPa 1
Recoil force of the gun at
maximum pressure
N 12.6
Motor Insulation - Class F
Motor Protection - IPX5
Voltage V/Hz 220 -
240/50
Sound Level: **(K = 3dB(A))
LPA (EN 60704-1)
LWA (EN 60704-1)
dB (A)
dB (A)
78.5
93.0
Unit Vibrations ***(K = 1.5m/s²) m/s2 < 2,5
Net Weight kg 7.2
Weight (Packed) kg 9.1
* Subject to technical modifications
** The sound intensity level for the operator may
exceed 78.5dB and ear protection measures are
necessary.
*** The declared vibration value has been measured
in accordance with a standard test method and
may be used for comparing one tool with another.
The declared vibration value may also be used in a
preliminary assessment of exposure.
WARNING! The vibration emission value during
actual use of the tool can differ from the declared
value depending on the ways in which the tool is used.
Identify safety measures to protect the operator that
are based on an estimation of exposure in the actual
conditions of use (taking account of all parts of the
operating cycle such as the times when the tool is
switched off and when it is running idle in addition to
the trigger time).
10

Related product manuals