63
“No Connection, Check Signal Cable” displays on screen.
Cause Solution
Computer is not turned on.
Monitor video cable is disconnected.
“Out of Range” displays on screen.
Cause Solution
Video resolution and refresh rate are set higher than what the
monitor supports.
High pitched noise coming from inside a flat panel monitor.
Cause Solution
Brightness and/or contrast settings are too high.
Fuzzy focus; streaking, ghosting, or shadowing effects; horizontal scrolling lines; faint vertical bars; or
unable to center the picture on the screen (flat panel monitors using an analog VGA input connection
only).
Cause Solution
Flat panel monitor’s internal digital conversion circuits may be
unable to correctly interpret the output synchronization of the
graphics card.
Graphics card is not seated properly or is bad.
Press the power button on the front of the monitor.
Connect the video cable between the monitor and computer.
CAUTION: Ensure that the computer power is off while
connecting the video cable.
Change the settings to a supported setting then restart the
computer so that the new settings take effect.
Lower brightness and/or contrast settings.
1. Select the monitor’s Auto-Adjustment option in the
monitor’s on-screen display menu.
2. Manually synchronize the Clock and Clock Phase onscreen
display functions.
1. Reseat the graphics card.
2. Replace the graphics card.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 100B SFF and is the answer not in the manual?

HP 100B SFF Specifications

Operating Environment IconOperating Environment
operating temperature range10° to 35°C
nonoperating temperature range-30° to 60°C
operating relative humidity10-90%
nonoperating relative humidity5-95%
operating maximum altitude3048 m
nonoperating maximum altitude9144 m
Power IconPower
operating voltage range90-137Vac
rated voltage range100-127Vac
rated line frequency50-60Hz
power output65 W
rated input current1.6A @ 90 VAC
Weight and Dimensions IconWeight and Dimensions
height27 cm
width10 cm
depth34.79 cm
weight4.8 kg