EasyManua.ls Logo

HP 16 processor - Page 15

HP 16 processor
63 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PA RISC Processors
PA RISC ProcessorsPA RISC Processors
PA RISC Processors
Itanium Processors
Itanium ProcessorsItanium Processors
Itanium Processors
PA-
PA-PA-
PA-
8600
86008600
8600
PA-
PA-PA-
PA-
8700
87008700
8700
PA-
PA-PA-
PA-
8700
87008700
8700
+
++
+
PA-
PA-PA-
PA-
8800
88008800
8800
PA-
PA-PA-
PA-
8900
89008900
8900
(sx
(sx(sx
(sx
1000)
1000)1000)
1000)
PA-
PA-PA-
PA-
8900
89008900
8900
(sx
(sx(sx
(sx
2000)
2000)2000)
2000)
Itanium
ItaniumItanium
Itanium
6M
6M6M
6M
Itanium
ItaniumItanium
Itanium
9M
9M9M
9M
mx2 dual
mx2 dualmx2 dual
mx2 dual
processor
processorprocessor
processor
module
modulemodule
module
Dual
DualDual
Dual
core
corecore
core
Itanium
ItaniumItanium
Itanium
1
11
1
PA 8600
PA 8600PA 8600
PA 8600
NA
Yes Yes
No No No No No No No
PA 8700
PA 8700PA 8700
PA 8700
Yes
NA
Yes
No No No No No No No
PA 8700 +
PA 8700 +PA 8700 +
PA 8700 +
Yes Yes
NA
No No No No No No No
PA 8800
PA 8800PA 8800
PA 8800
No No No
NA
Yes
No No
Yes
No No
PA 8900
PA 8900PA 8900
PA 8900
(for
(for(for
(for
sx1000)
sx1000)sx1000)
sx1000)
No No No
Yes
NA
No No
Yes
No No
PA-8900
PA-8900PA-8900
PA-8900
(1.068GHz
(1.068GHz(1.068GHz
(1.068GHz
for sx2000)
for sx2000)for sx2000)
for sx2000)
No No No No No
NA
No
Yes
No
Yes
Itanium 6M
Itanium 6MItanium 6M
Itanium 6M
(sx1000)
(sx1000)(sx1000)
(sx1000)
No No No No No
NA NA
Yes Yes
No
Itanium 9M
Itanium 9MItanium 9M
Itanium 9M
(sx1000)
(sx1000)(sx1000)
(sx1000)
No No No
Yes Yes
No
Yes
NA
Yes
No
mx2 Dual
mx2 Dualmx2 Dual
mx2 Dual
processor
processorprocessor
processor
Module
ModuleModule
Module
(sx1000)
(sx1000)(sx1000)
(sx1000)
No No No No No
Yes Yes Yes
NA
No
Itanium 9M
Itanium 9MItanium 9M
Itanium 9M
(sx2000)
(sx2000)(sx2000)
(sx2000)
No No No No No
Yes
No
N/A
No
Yes
Dual core
Dual coreDual core
Dual core
Itanium
ItaniumItanium
Itanium
(sx2000)
(sx2000)(sx2000)
(sx2000)
No No No No
Yes
(future)
No No
Yes
No
NA
2)
2)2)
2)
In order to run an Itanium-based partition in an Integrity server, what changes are required?
In order to run an Itanium-based partition in an Integrity server, what changes are required?In order to run an Itanium-based partition in an Integrity server, what changes are required?
In order to run an Itanium-based partition in an Integrity server, what changes are required?
In order to add a new partition with Itanium 9M processors on an HP 9000 Superdome, the following
steps are required:
Step #1: Upgrade firmware on PA-RISC based partitions
Step #2: Create a new hard partition in the Superdome for Itanium based cell (s)
Step #3: Plug in cell boards for Itanium based cells
Step #4: Some I/O cards may need to be added for that specific hard partition (Windows does not
support the identical set of I/O cards that HP-UX 11i supports)
Step #5: Load operating system for Itanium based partition
Upgrading a PA-RISC partition to support Itanium processors would require similar steps:
Step #1: Upgrade firmware on PA-RISC based partitions
Step #2: Pull out existing PA-RISC cell boards
QuickSpecs
HP Integrity Superdome Servers 16- processor, 32-
HP Integrity Superdome Servers 16- processor, 32-HP Integrity Superdome Servers 16- processor, 32-
HP Integrity Superdome Servers 16- processor, 32-
processor, and 64- processor Systems
processor, and 64- processor Systemsprocessor, and 64- processor Systems
processor, and 64- processor Systems
Configuration
DA - 11717 Worldwide — Version 57 — October 23, 2009
Page 15

Related product manuals