EasyManua.ls Logo

HP 16 processor - Page 52

HP 16 processor
63 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Control panel
Multi-function LCD status and control console
Audible alarm
Beep for each 52 alarm conditions
Emergency power off
(EPO)
Yes
Optional management
device
See APC website
http://www.apcc.com
Environmental
EnvironmentalEnvironmental
Environmental
Operating environment
32° to 104°F (0° to 40 °C)
Operating relative
humidity
0% to 95%
Operating elevation
0 to 3333 ft (0 to 999.9 m)
Storage temperature
-58° to 104°F (-50° to 40 °C)
Storage relative humidity
0% to 95%
Storage elevation
0 to 50,000 ft (0 to 15,000 m)
Audible noise at 1 meter
from surface of unit
55 dBA
Protection class
4,094 BTU/hour
NEMA 1, NEMA 12 optional
Online thermal dissipation
4,094 BTU/hour
Protection Class
NEMA 1, NEMA 12
Conformance
ConformanceConformance
Conformance
Approvals
EN 55022 Class A, ISO 9001, ISO 14001, UL
1778, UL Listed, cUL Listed
Standard warranty
One-year repair or replace, optional on-site
warranties available, optional extended
warranties available
Optional new service
See APC website
http://www.apcc.com
1
The time to recharge to 90% of full battery capacity following a discharge to shutdown using a load
rated for 1/2 the full load rating of the UPS
sx2000 Superdome supported I/O
sx2000 Superdome supported I/Osx2000 Superdome supported I/O
sx2000 Superdome supported I/O
NOTE:
NOTE:NOTE:
NOTE:
While ordering Windows Server 2008, do not mix differing brands of HBAs (Emulex and Qlogic) within the same server
configuration in an MPIO environment.This is to avoid issues which occur when different Fibre Channel HBAs are used within the
same server which support different I/O max transfer packet sizes in an MPIO environment. For example, the Emulex Fibre Channel
HBAs support a max I/O transfer packet size of 1MB and the Qlogic Fibre Channel HBAs support a max I/O transfer packet size of
2MB. Mixing these two cards in an MPIO configuration can cause the system to hit a BSOD 0X000000D1 with a reference to
elxstor.sys
This applies to the following products:
Emulex:
Emulex:Emulex:
Emulex:
HP StorageWorks single port 8 Gigabit PCI-e FC Emulex HBA (AH402A)
HP StorageWorks dual port 8 Gigabit PCI-e FC Emulex HBA (AH403A)
HP StorageWorks 2 Gb Fibre Channel HBA (AB232A)
HP StorageWorks 2 Gb, 64-Bit/133 MHz PCI-X-to-Fibre Dual Channel HBA (AB466A)
HP StorageWorks 2 Gb, 64-Bit/133 MHz PCI-X-to-Fibre Single Channel HBA (AB467A)
HP StorageWorks 4 Gb Single Port 64-bit 266 MHz Fibre Channel HBA (AD167A)
HP StorageWorks 4 Gb Dual Port 64-bit 266 MHz Fibre Channel HBA (AD168A)
HP StorageWorks FC2142 PCIe Single Port 4 Gb Fibre Channel adapter (A8002A)
QuickSpecs
HP Integrity Superdome Servers 16- processor, 32-
HP Integrity Superdome Servers 16- processor, 32-HP Integrity Superdome Servers 16- processor, 32-
HP Integrity Superdome Servers 16- processor, 32-
processor, and 64- processor Systems
processor, and 64- processor Systemsprocessor, and 64- processor Systems
processor, and 64- processor Systems
Technical Specifications
DA - 11717 Worldwide — Version 57 — October 23, 2009
Page 52

Related product manuals