EasyManua.ls Logo

HP 5335A - Page 72

HP 5335A
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
and
Programming
3-211,
OPTIONS
3-212.
The
operating
characteristics
of
the
5335A
are
affected
by
the
addition
of
any
of
the
options
described
in
the
following
paragraphs.
3-213,
Time
Base
Option
010
3-214,
Option
010
provides
an
Oven-Controlled
Crystal
Oscillator
Time
Base,
that
results
in
higher
accuracy
and
longer
periods
between
calibration
(refer
to
Table
1-1).
The
oven
temperature
is
maintained
when
the
5335A
LINE
switch
is
in
either
the
ON
or
the
STBY
position
(provided
the
instrument
is
connected
to
the
power
mains).
NOTE
The
Option
010
Oven-Controlled-Oscillator,
HP
Model
10811
A,
is
a
direct
replacement
for
the
previous
HP
Model
10544A.
Service
documentation
for
the
older
10544A
is
provided
in
SECTION
VIiI
under
Assembly
A12
Oven
Oscillator.
All
service
documentation
for
the
newer
HP
1Q811A
is
provided
in
the
HP
10811A
Operating
and
Service
Manual,
(HP
Part
Number
10811-90002)
included
with
Option
010.
3-215.
Digital
Voltmeter
Option
020
3-216.
Option
020
provides
a
fully
floating,
autoranging
digital
voltmeter.
This
module
measures
dc
inputs
up
to
1000
volts
through
front
panel
connectors.
Refer
to
Specificatons,
Table
1-1,
for
the
specific
operating
characteristics.
3-217.
C
Channel
Option
030
3-218.
Option
030
provides
a
C
Channel
Input
Module,
which
expands
the
frequency
counting
range
of
the
counter
to
1.3
GHz.
A
front
panel
control
adjusts
the
input
sensitivity.
A
front
panel
preamp
power
receptacle
is
provided.
Refer
to
Specifications,
Table
1-1,
for
the
specific
operating
characteristics.
3-219.
OPERATOR'S
MAINTENANCE
3-220.
The
only
maintenance
the
operator
should
normally
performs
is
replacement
of
the
primary
power
fuse
located
within
the
Line
Module
Assembly.
For
instructions
on
how
to
change
the
fuse,
refer
to
Section
II,
Line
Voltage
Selection.
fc
autionI
Make
sure
that
only
fuses
with
the
required
rated
current
and
of
the
slow-bfow
type
are
used
for
replacement.
The
use
of
re¬
paired
fuses
and
the
short-circuiting
of
fuse-holders
must
be
avoided.
3-221.
When
Option
030
C
Channel
is
installed,
the
operator
may
be
required
to
replace
the
input
BNC
fuse.
This
is
a
1/8A
fuse
(HP
Part
No.
2110-0301)
which
is
located
within
the
INPUT
C
BNC
connector
(see
Figure
3-4
for
details).
To
replace
the
fuse,
disconnect
the
power
cord,
unscrew
the
special
BNC
barrel
(P/N
05305-60205)
and,
with
needle-nose
pliers,
remove
and
replace
the
fuse.
Reinstall
the
BNC
barrel,
and
tighten
using
a
BNC
cable
connector.
Be
careful
not
to
overtighten.
3-56
Model