EasyManuals Logo

HP 6038A Service Manual

HP 6038A
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
Number
Controls/Indicators
Description
LCL
Pushbutton
Returns
unit
to
local
control
(unless
local
lockout
has
been
received
via
HP-IB).
in
local,
power
supply
remains
subject
to
remotely
pro¬
grammed
soft
limits
and
delays.
When
held
in
for
one
second,
LCL
causes
HP-IB
address
to
be
displayed
for
up
to
two
seconds
or
until
LCL
switch
is
released.
HP-IB
Status
Indicators
RMT
(green)
indicates
that
power
supply
is
under
remote
(HP-IB)
control.
These
four
LEDs
indicate
the
status
of
the
power
LSN
(green)
indicates
that
power
supply
supply
on
the
HP-!B.
is
addressed
to
listen.
TLK
(green)
indicates
that
power
supply
is
addressed
to
talk.
SRQ
(green)
indicates
that
power
supply
is
requesting
service
from
controller.
Power
Supply
Status
CV
(green)
indicates
that
the
power
supply
is
Indicators
(Primary)
regulating
its
output
at
a
constant
voltage.
These
four
LEDs
indicate
the
CC
(green)
indicates
that
the
power
supply
is
operating
state
of
the
power
regulating
its
output
at
a
constant
current.
supply.
Usually
only
one
LED
is
on,
but
both
CV
and
CC
OVERRANGE
(yellow)
indicates
that
the
power
can
be
on
together
if
unit
supply
is
operating
beyond
its
maximum
is
operating
at
crossover
output
power
specification
and
that
the
point
between
CV
and
CC.
output
is
not
regulated.
DISABLED
(yellow)
indicates
that
the
power
supply
output
has
been
turned
off
for
one
of
these
reasons:
a.
command
from
controller
b.
overvoltage
protection
c.
overtemperature
protection
d.
foidback
protection
e.
low
or
high
ac
input
voltage
f.
remote
inhibit
Power
Supply
Status
OV
(yellow)
indicates
that
the
overvoltage
Indicators
(Secondary)
protection
circuit
has
disabled
the
output
and
is
latched.
These
four
LEDs
indicate
the
state
of
protective
circuits
OT
(yellow)
inidcates
that
the
overtemperature
within
the
power
supply.
protection
circuit
has
disabled
the
output.
FOLDBACK
(yellow)
indicates
that
the
foidback
protection
circuit
has
disabled
the
output
and
is
latched.
ERROR
(yellow)
indicates
that
the
power
supply
has
detected
a
programming
error.
3-73-3-75,3-94
3-68,
3-74
3-79
3-79
3-80-3-83
3-17d
3-17j
3-10-3-11,3-58
3-59
3-17g,
3-60
3-61
3-35-3-39,
3-63,
3-145
3-17f,l,3-64
3-183-3-185
3-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 6038A and is the answer not in the manual?

HP 6038A Specifications

General IconGeneral
BrandHP
Model6038A
CategoryInverter
LanguageEnglish

Related product manuals