3-211
Foldback
protection,
if
desired,
may
only
bo
used
with
the
master
power
supply.
3-212
Figure
3-14
shows
the
rear-pane!
MODE
switch
set¬
tings
and
terminal
connections
for
auto-parallel
operation.
This
configuration
provides
0
to
60
Vdc
at
an
output
current
of
up
to
20
Adc.
3-213
Setting
Voltage
and
Current.
Program
the
slave
unit's
output
voltage
above
the
master's
to
avoid
interference
with
master-unit
CV
control.
The
slave
unit's
MODE
switches
disable
the
slave
unit's
current
setting
from
having
any
effect
In
auto-parallel
operation.
Program
the
master
unit
to
the
desired
output
voltage
and
current.
Verity
that
the
slave
is
in
CC
operation.
3-214
When
in
CV
operation,
the
master
unit's
voltage
set¬
ting
is
the
output
voltage
of
the
auto-parallel
combination.
The
output
current
is
the
total
current
from
all
units.
The
fraction
of
total
current
that
each
unit
provides
is
the
same
as
the
ratio
of
that
unit's
output
current
capability
to
the
total
output
cur¬
rent
capability
of
the
auto-parallel
combination.
3-215
In
CC
operation,
the
user
must
add
up
the
current
outputs
from
each
unit
and
adjust
the
master
until
the
total
equals
the
desired
load
current.
LOAD
Figure
3-14.
Auto-Parailel
Operation
3-216
Overvoltage
Protection.
Adjust
the
desired
OVP
shut¬
down
limit
using
the
master
unit's
OVP
ADJUST
control.
Set
the
slave
unit's
OVP
limit
above
the
master's.
When
the
master
unit
shuts
down,
the
master
programs
the
slave
unit
to
zero
voltage
output.
If
a
slave
unit
shuts
down
(because
its
OVP
shutdown
limit
is
set
lower
than
the
master's),
it
shuts
down
only
itself,
and
the
other
unit
supplies
all
the
load
current.
The
shut-down
slave
unit
will
draw
some
current
through
its
down
programming
circuit.
The
extra
current
required
from
the
master
unit
may
cause
the
master
to
switch
from
CV
to
CC
mode.
3-217
Remote
Sensing.
To
remove
sense
with
auto¬
parallel
operation,
connect
remote-sense
leads
only
to
the
master
unit
according
to
the
remote-sensing
Instructions
In
paragraph
3-40.
3-218
Remote
Programming.
To
remove
program
with
auto-parallel
operation,
set
up
only
the
master
unit
for
remote
programming.
NOTE
Down-programming
speed
is
slower
with
auto¬
parallel
operation
because
only
the
master
unit's
down
programmer
operates.
'.3
w
VW
IM
1
A
Vm
VP
VP
a
IP
IP
.-1
MOnE
MODE
06
06
m
I...J
:
'
ii:
;i
m
I
»
m
.!
»
01
8<
a
1
a
1
+s
-s
^
+s
-s
FI
1
-
'
VvV-
J
LOAD
Figure
3-15.
Series
Operation
3-28