Contents 
Figure 
ilST  OF  ILLUSTRATIONS 
Page 
Figure 
HP  8673WD 
Page 
l-l. 
1-2. 
2-l. 
22. 
2-3. 
2-4. 
2-6. 
n 
1  51. 
3-2. 
3-3. 
84. 
3-5. 
3-6. 
HP  8673C/D  Accessories  Supplied, 
and  Options  908 and  913 
.................  .1-O 
Special  Interconned  Cable  ................ 
. l-17 
Line  Voltage  and  Fuee  Selection  ............ 
.%2 
Power  Cable  and  Mains  Plug  Part 
Numbers  ................................. 
.2-2 
HP-IB  Address  Switch  Shown  a8 Set  by 
theFactory..  ........................... 
..2  3 
Hewlett-Packard  Interface  Bus 
Connection..  ............................. 
25 
AWX  Interface  Connector  .................. 
.%6 
Front  Panel  Features  ....................... 
.32 
Displays  and  Statue  Annunciators  .......... 
.58 
output  Level  Features  ..................... 
.3-9 
Frequency  Control  features  and  LINE 
switch  ................................. 
..510 
Sweep  Features  and  LOCAL  Key  .......... 
,911 
Modulation  Features  ...................... 
.S-12 
57. 
3-a. 
s-9, 
S-10. 
Sll. 
4-l. 
4-2. 
4-3. 
4-4. 
4-5. 
4-6. 
4.7. 
4-8. 
49. 
Rear  Panel  Features 
....................... 
.913 
AM  Fuixtional  Check  Setup 
............... 
,318 
FM  Functional  Check  Setup 
................ 
S-19 
Pulse  Modulation  Functional  Check 
setup  .................................... 
Z-20 
Statue  Byte  Information., 
................. 
,340 
Frequency  Range  and  Resolution  Test 
setup  .  .  . , , .  . .k3 
High  Level  Accuracy  and  Flatness 
Test  Setup  *.  , .  .  .  .  , . .4-6 
Low  Level  Accuracy  Test  Setup  . *,.  , . ,  .4-10 
FM/AM  Accuracy  Test  Setup.  .  .  , .  .4-13 
AM  Accuracy  Test  Setup  . , , .  .4-15 
Low  Frequency  Pulse  Test  Setup..  , . , , .  .4-17 
Rise  Time,  Overshoot  and  Ringing 
Measurement  .  .  t t  .  .  . .4-17 
Pulse  Level  Accuracy  Measurement..  .  . . .4-18 
High  Frequency  Pulse  Test  Setup  .  . . t 4-19 
TABLES 
Table  Page  Table  Page 
1.1. 
1-2. 
13. 
1-4. 
2-l. 
3-L 
3-2. 
3-3. 
3-4. 
Specitications  ............................... 
l-4 
Supplemental  Characteristics  .............. 
l-11 
Recommended  Test  Equipment 
............  . l-14 
Operation  Verification  Recommended 
Test  Equipment  ........................... 
l-18 
Allowable  HP-IB  Address  Codes 
.............  %3 
Operating  Characteristics  .................. 
.3-l 
(Reserved  for  final  manual), 
................  .55 
AWX  Connector  Functions  ................ 
,530 
Message  Reference  Table  ................... 
3-32 
as. 
56. 
37. 
34. 
4-l. 
4.2. 
4.3. 
4.4. 
4.5. 
4-6. 
Talk  Functions  ............................ 
.3-37 
Response  to a  Clear  Message 
............... 
Z-38 
HP-IB  Program  Codes 
..................... 
.3-41 
Messages.. 
..............................  ..4-4  2 
Maximum  Leveled  Output  Power  ........... 
4-7 
Level  Flatness 
............................. 
4-9 
High  Level  Accuracy  ...................... 
4-9 
Low  Level  Accuracy  ...................... 
4-12 
Risetime,  Overshoot,  and  Peak  Level 
Accuracy  ................................ 
4-20 
Operation  Verification  Test  Record  ........  4-21 
iv