EasyManua.ls Logo

HP 8753D - Page 625

HP 8753D
678 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A
TN (Attention)
The active
controller uses
this line
to dene
whether
the
information on
the data
bus is
command-oriented or
data-oriented.
When this
line is
true (low),
the bus
is in
the
command
mode,
and the
data lines
carry bus
commands
.
When
this
line is
false (high),
the bus
is in
the
data
mode
,
and
the
data
lines carry
device-dependent instructions
or data.
SRQ
(Service Request)
This line
is set
true
(low)
when
a
device
requests
service
and
the active
controller
services
the
requesting
device
.
The
network
analyzer can
be
enabled
to
pull
the
SRQ
line
for
a
variety
of reasons
such
as
requesting
control
of
the
interface
,
for
the purposes
of
printing,
plotting,
or
accessing
a
disk.
REN
(Remote Enable)
This line
is
used
exclusively
by
the
system
controller
.
When
this
line
is
set
true
(low),
the
bus
is
in
the
remote
mode
,
and
devices
are
addressed
by
the
controller
to
either
listen
or
talk.
When
the
bus
is
in
remote
mode
and
a
device
is
addressed,
it
receives
instructions
from
the
system
controller
via
HP-IB
rather
than
from
its
front
panel
(pressing
4
LOCAL
5
returns
the
device
to
front-panel
operation). When
this
line
is
set
false
(high),
the
bus and
all of
the
connected
devices
return
to
local
operation.
EOI (End
or Identify)
This line
is
used
by
a
talker
to
indicate
the
last
data
byte
in
a
multiple-byte transmission,
or by
an
active
controller
to
initiate
a parallel-poll
sequence.
The
analyzer
recognizes
the
EOI
line
as a
terminator,
and
it
pulls
the
EOI
line
with
the
last
byte
of
a
message
output
(data,
markers
,
plots
,
prints
,
error
messages).
The
analyzer
does
not
respond
to
parallel
poll.
HP-IB
Requirements
Number
of
Interconnected Devices:
15 maximum.
Interconnection
P
ath Maximum
Cable Length:
20
meters
maximum
or
2
meters
per
device
(whichever is
less).
Message
Transfer
Scheme: Byte
serial, bit
parallel a
synchronous
data
transfer
using
a 3-line
handshake system.
Data Rate:
Maximum
of
1
megabyte-per-second
over
the
specied distances
with
tri-state
drivers
.
A
ctual
data rate
depends on
the transfer
rate
of
the
slowest
device
connected
to
the bus
.
Address Capability:
Primary addresses: 31 talk, 31 listen. A
maximum of 1 talker and 14 listeners can be
connected to the interface at given time
.
Multiple-Controller Capability:
In systems with more than one controller (like
this instrument), only one controller can be
active
at any given time
. The active controller
can pass
control to another controller
, but only
the system controller can assume unconditional
control. Only one
system
controller is allowed.
Compatible Peripherals 11-17

Related product manuals