Do you have a question about the HP 8753D Option 011 and is the answer not in the manual?
Dynamic Range | >100 dB |
---|---|
Display Type | CRT |
Number of Channels | 2 |
Impedance | 50 Ω |
Number of Data Points | 1601 |
Measurement Parameters | S11, S21, S12, S22 |
Interface | GPIB (IEEE-488) |
Option 011 | Frequency extension to 6 GHz |
Frequency Range | 30 kHz to 3 GHz (Option 011 extends to 6 GHz) |
Lists required test equipment and their specifications.
Provides guidelines for proper connector care and connection techniques.
Details optional features for the analyzer, like frequency references.
Outlines available service and support packages for product warranty and calibration.
Record for analyzers with a frequency range of 300 kHz to 3 GHz.
Record for analyzers with a frequency range of 30 kHz to 6 GHz.
Procedures to follow after repair to ensure proper instrument function.
Covers default, pre-tune, RF output, and sensor calibration routines.
Procedures for setting serial numbers, options, and calibration data.
Adjustments for frequency range, spur avoidance, and tracking.
Steps for replacing an assembly in the HP 8753D Network Analyzer.
Initial observations, self-tests, and operator checks for analyzer functionality.
Verifies HP-IB systems, plotter/printer, and external disk drive connectivity.
Procedure to isolate faulty groups within the analyzer.
Checks for power supply, digital control, source, and receiver issues.
Steps for replacing a power supply assembly.
Verifies status of diagnostic LEDs on A15 preregulator and A8 post regulator.
Measures DC voltages and verifies preregulator output.
Addresses abnormal LED status, temperature, and faulty assemblies.
Steps for replacing a source assembly.
Prerequisites and initial checks for source power levels.
Addresses phase lock errors and related troubleshooting procedures.
Checks for sampler/mixer, phase lock, and reference signal issues.
Checks digital control signals and Fractional-N parameters.
Steps for replacing a receiver assembly.
Lists and explains error messages related to receiver failures.
Verifies flatness of R, A, B input traces and handles cases where all inputs are bad.
Checks reference signals and LO signals for receiver operation.
Steps for replacing accessories.
Inspects accessories, connectors, switch repeatability, and error terms.
Troubleshooting procedures for test sets.
Overview of service menus, internal diagnostics, and test selection.
Details test descriptions and available service features.
Explains the analog bus and the functions of specific nodes.
Lists and explains error messages encountered during analyzer operation.
Explains the diagnostic role and definitions of various error terms.
Procedure for performing full two-port error correction.
Inspects error terms and reviews uncorrected performance data.
Overview of analyzer operation and the synthesized source.
Explains power supply theory, preregulator, and power module functions.
Details the analyzer's functional groups: Power Supply, Digital Control, Source.
General steps and safety precautions for assembly replacement.
Procedures for replacing front panel components and interfaces.
Procedures for replacing core functional assemblies like source, samplers, CPU.
Procedures for replacing rear panel, display, disk drive, and fan.
Information on product specifications, warranty, and customer support.
Explains safety symbols, markings, general precautions, and servicing warnings.