sampler is
also related
since it
is part
of the
source
phase
lo
c
k
lo
op.
The
source
supplies
a
phase-lo
c
k
ed
RF
signal
to
the
device
under
test.
Signal
Separation.
The
signal separation
group divides
the source
signal in
to a
reference
path and
a test
path,
and
pro
vides
connections
to
the
device
under
test.
T
o accomplish
this,
one
of
sev
eral
external
test sets
must
be
connected to
the analyzer.
Receiv
er.
The
receiver
group consists
of the
A4/A5/A6
sampler/mixers
and
the
A10
digital
IF.
The
A12
reference
assem
bly
and
the
A9
CPU
are
also
related.
The
receiv
er
measures
and
pro
cesses
input
signals
for
displa
y
.
The
follo
wing
pages
describ
e
the
operation
of eac
hof
the functional
groups.
P
o
w
er
Supply
Theory
The
p
o
w
er
supply
functional
group consists
of the
A15
preregulator
and
the
A8
p
ost
regulator.
These
t
wo
assem
blies
comprise
a
switc
hing
p
o
w
er
supply
that
pro
vides
regulated
DC
v
oltages
to
p
o
w
er
all
assem
blies
in
the
analyzer.
The
A15
preregulator
is
enclosed
in
a
casting at
the rear
of
the
instrumen
t
b
ehind
the
displa
y
.
It
is
connected
to
the
A8
p
ost
regulator
b
y
a
wire
bus
A15W1. Figure
12-2 is
a simplied
blo c
k
diagram
of
the
p
o
w
er
supply
group.
Figure
PSBLK12
here.
Figure 12-2. P
o
wer Supply Functional Group, Simplified Block Diagram
A15 Preregulator
The
A15 preregulator steps do
wn and recties the line v
oltage. It pro
vides a fully regulated
+5 V digital supply, and several preregulated voltages that go to the A8 post regulator
assembly for additional regulation.
The A15 preregulator assembly includes the line power mo dule, a 60 kHz switching
preregulator, and overvoltage protection for the +5 V digital supply.Itprovides LEDs, visible
from the rear of the instrument, to indicate either normal or shutdown status.
12-4 Theory of Operation DRAFT
3/21/106 15:14
Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 8753D Option 011 and is the answer not in the manual?

HP 8753D Option 011 Specifications

General IconGeneral
BrandHP
Model8753D Option 011
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals