Power supply
1. Remove the flatbed scanner assembly. See Flatbed scanner assembly on page 96.
2. Remove three screws (callout 1) from the upper ribbon guide, slide the ribbon cable off of the guide,
and then lift the guide out of the device.
1
Figure 5-82 Removing the power supply (1 of 6)
3. Disconnect the middle cable connector (callout 2) from the interconnect board.
2
Figure 5-83 Removing the power supply (2 of 6)