EasyManuals Logo

HP A Series User Manual

HP A Series
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
2-15
INPUT
POWER
REQUIREMENTS
2-16
The
modular
power
supplies
may
be
operated
from
a
nominal
120
Vac,
220
Vac,
or
240
Vac,
48-63
Hz,
power
source.
The
standard
supply
(no
options)
is
shipped
from
the
factory
wired
for
120
Vac
(nominal)
operation
and
requires
the
following
maxi¬
mum
input
current
and
power
at
high
line
(127
Vac)
voltage
input:
AC
INPUT
at
127
Vac
MODEL
CURRENT
(Max.)
POWER
(Max.)
62003A
.30A
31W
62003C
.77A
74W
62003E
1.38A
143W
62004A
.33A
34W
62004C
.78A
76W
62004E
1.42A
149W
62005A
.37A
37W
62005C
.80A
79W
62005E
1.53A
160W
62006A
.36A
37W
62006C
.80A
79W
62006E
1.56A
161W
6201OA
.39A
39W
62010C
.98A
97W
62010E
1.87A
192W
52012A
.47A
47W
62012C
1.00A
100W
62012E
1.89A
191W
62015A
.45A
46W
62015C
.99A
97W
62015E
1.82A
181W
62018A
.42A
42W
62018C
.97A
95W
62018E
1.93A
196W
62024A
.39A
39W
62024C
.93A
88W
62024E
1.95A
198W
62028A
.44A
44W
62028C
.91
A
86W
62028E
1.87A
190W
62048A
.47
A
47W
62048C
.97A
95W
62048E
2.00A
193W
2-17
220/240
VOLT
OPERATION
2-18
As
applicable,
Options
101,102,
and
103
(in¬
stalled
at
the
factory)
permit
the
supply
to
be
operated
from
a
120,
220,
or
240
Vac
(nominal)
input
line.
Option
101
provides
for
220
Vac
operation
while
Option
102
allows
240
Vac
operation.
Option
103,
however,
provides
for
either
120
Vac
or
240
Vac
oper¬
ation
at
the
selection
of
the
user
as
described
below.
2-19
Option
103
Power
Transformer
Connections,
A—
suffix
Models.
For
the
A-
suffix
models,
the
pri¬
mary
connections
of
the
supply
are
changed
at
the
in¬
board
side
of
the
rear
power
input
terminals.
For
120
Vac
operation
(as
shipped),
two
leads
are
soldered
from
each
of
the
ac
input
terminals
as
shown
in
Figure
2-2B.
To
connect
the
supply
for
240
Vac
oper¬
ation,
unsolder
the
wht/bik/yel
and
wht/blk/grn
leads
and
twist
them
together
with
a
wire
terminal
as
shown
in
Figure
2-2A.
Figure
2-2.
Primary
Connections
For
120/240
Vac
Operation
(Option
103)
A
Suffix
Models
Only
2-20
Option
103
Power
Transformer
Connections,
-C
and
E-
Suffix
Models.
For
the
C-
and
E-
suffix
models,
the
appropriate
power
transformer
120/240
V
terminals
must
be
connected
as
shown
in
Figure
2-3.
Notice
that
the
transformer
connections
are
changed
at
the
transformer
terminals
shown
in
the
illustration.
2-3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP A Series and is the answer not in the manual?

HP A Series Specifications

General IconGeneral
ModelHP A Series
CategoryPower Supply
Input Voltage100-240V AC
Input Frequency50/60 Hz
CoolingFan
ConnectorsSATA, Molex
Efficiency80% or higher (80 Plus Certified)

Related product manuals