EasyManua.ls Logo

HP A7533A - Brocade 4Gb SAN Switch Base

HP A7533A - Brocade 4Gb SAN Switch Base
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
In the event of the GL node failing to come back up, the GL node can be replaced with a new
node. The following are the procedures to allow an EG to function with existing member nodes
and to replace the failed GL node with a new node.
Make one of the existing member nodes the Group Leader node and continue operations.
1. On one of the member nodes, create the EG with the same EG name. This will make that
node the GL node and the rest of the CTC and Tape Pool related configurations will remain
intact in this EG.
2. For any containers hosted on the failed GL node, issue cryptocfg --replace to
change the WWN association of containers from the failed GL node to the new GL node.
Replace the failed GL node with a new node.
1. On the new node, follow the switch/node initialization steps.
2. Create an EG on this fresh switch/node with the same EG name as before.
3. Perform a configdownload to the new GL node of a previously uploaded configuration
file for the EG from an old GL node.
4. For any containers hosted on the failed GL node, issue cryptocfg --replace to
change the WWN association of containers from failed GL node to the new GL node.
During an online upgrade from Fabric OS 6.2.0x to 6.3.0, we expect to see the I/O link status
reported as Unreachable when the cryptocfg command is invoked. However, once all the
nodes are upgraded to Fabric OS 6.3.0, the command will accurately reflect the status of the I/O
Link. The I/O link status should be disregarded during the code upgrade process.
The key_lifespanoption has no effect for cryptocfg add LUN, and only has an effect
for cryptocfg --create tapepool for tape pools declared -encryption_format
native. For all other encryption cases, a new key is generated each time a medium is rewound
and block zero is written or overwritten. For the same reason, the Key Life field in the output of
cryptocfg --show -container -all stat should always be ignored, and the Key Life
field in cryptocfg --show tapepool cfg is significant only for native-encrypted pools.
The Quorum Authentication feature requires DCFM 10.3.0 or later. Note that all nodes in the EG
must be running Fabric OS 6.3.0 for quorum authentication to be properly supported.
In a DC SAN Director or DC04 SAN Director with Fabric OS 6.3.0 and DC Switch encryption
FC blades installed, you must set the quorum size to zero and disable the system card on the blade
prior to downgrading to a Fabric OS version earlier than 6.3.0.
The System Card feature requires DCFM 10.3.0 or later. Note that all nodes in the EG must be
running Fabric OS 6.3.0 for system verification to be properly supported.
The Encryption SAN Switch and Encryption FC blade do not support QoS. When using encryption
or Frame Redirection, participating flows should not be included in QoS Zones.
HP encryption devices can be configured for either disk or tape operation. The ability to configure
multiple Crypto-Target Containers defining different media types on a single encryption engine
(Encryption SAN Switch or Encryption FC blade) is not supported. Encryption FC blades can be
configured to support different media types within a common DC SAN Director/DC04 SAN Dir-
ector chassis.
SKM is supported with Multiple Nodes and Dual SKM Key Vaults. Two-way certificate exchange
is supported. See the Encryption Admin Guide for configuration information. If you are using dual
SKMs on Encryption SAN Switch/Encryption FC blade Encryption Group, these SKM Appliances
must be clustered. Failure to cluster will result in key creation failure. Otherwise, register only one
SKM on the Encryption SAN Switch/Encryption FC blade Encryption Group.
When the tape key expires in the middle of write operation on the tape, the key is used to append
the data on the tape media. When the backup application rewinds the media and starts writing
HP StorageWorks Fabric OS 6.3.0c Release Notes 41

Other manuals for HP A7533A - Brocade 4Gb SAN Switch Base

Related product manuals