43
The 16 Processor model consists of a cabinet with two 8P drawers and may or
may not have an expander cabinet. Power is in the cabinet with the 8p drawers
1. Unpack and de-skid the system.
2. Roll the cabinets to the desired location and arrange them according to
the cabinet placement rules for the given system.
3. If applicable, follow the procedure for installing an expander cabinet.
4. Level the system using the four leveling feet at the bottom four corners of
the cabinet. Lower the leveling feet until the castor in each corner are free
to rotate and the feet, not the castors, support the weight of the cabinet.
At the rear of each cabinet you will find an extension bar with two non-
load-bearing leveling feet - they should be lowered until they make contact
with the floor.
(insert graphic of leveling feet)
5. Remove the orange shipping brackets and their screws; save them with
the system for use later should the system be moved.
6. There are two orange shipping brackets at the back that secure the I/O
drawers to the cabinetās side rails. On each side, remove the brackets
and screws; save them with the system for use later should the system be
moved.
7. All cable connections should be made in a single cabinet system. Check
to make sure that cables are secure.
8. Connect to and set up the NAT box.
9. Connect the console.
10. Verify the installation.