3. Show the detailed environment of drawer 0 in cabinet 0.
MBM> sh power -ca 0 -dr 0 -detail
SBB: cabinet = 0, drawer = 0
Power state: ON
Temperatures(in centigrade):
MBM: 29.0 (P) OCP: 23.0 (P)
Fans(in RPM):
Front Fan: 2008 (P) Back Fan: 2008 (P)
Power Interface: cabinet = 1, drawer = 0, type = WPI, slot = 0, status = OK
Power Supplies:
PWR0.PS0: ON PWR0.PS1: ... PWR0.PS2: ON
Voltages:
MBM 2.5V: 2.457V (P) MBM 3.3V: 3.294V (P) MBM 5.0V: 4.915V (P)
DUO0: cabinet = 0, drawer = 0
Power state: ON
Temperatures(in centigrade):
CMM: 21.5 (P) CPU0: 31.1 (P) CPU1: 28.1 (P)
Voltages:
EV7 Core 1.575V: 1.580V (P) Term Volt 1.835V: 1.870V (P)
RIMM Volt 2.523V: 2.496V (P) EV79 Core 0.000V: 0.000V (P)
CMM Volt 3.300V: 3.230V (P)
VRMs:
CPU RIMM Term
012345 01234 0
PPPPP. ..PPP PP
DUO1: cabinet = 0, drawer = 0
Power state: ON
Temperatures(in centigrade):
CMM: 26.0 (P) CPU0: 31.6 (P) CPU1: 30.1 (P)
Voltages:
EV7 Core 1.575V: 1.570V (P) Term Volt 1.783V: 1.830V (P)
RIMM Volt 2.523V: 2.496V (P) EV79 Core 0.000V: 0.000V (P)
CMM Volt 3.300V: 3.213V (P)
VRMs:
CPU RIMM Term
012345 01234 0
PPPP.. ..PPP PP
MBM>
4. Show the detailed environment of PCI drawer 3 in cabinet 0.
MBM> sh power -ca 0 -dr 3 pci -detail
PCI Drawer: cabinet = 0, drawer = 3
Temperatures(in centigrade):
PBM: 27.5 (P) PCI_0: 24.5 (P) PCI_1: 25.0 (P)
OCP: 24.5 (P) PS0: 24.0 (P) PS1: 27.0 (P)
Fans(in RPM):
Fan 0: 2721 (P) Fan 1: 2766 (P) Fan 2: 2766 (P)
Power Supplies:
PS0: ON PS1: ON
Voltages:
PBM 2.5V: 2.470V (P) PBM 3.3V: 3.294V (P) PBM 5.0V: 4.915V (P
PCI 1.5V: 1.500V (P) PCI 2.5V: 2.540V (P) PCI 3.3V: 3.329V (P)
PCI 5.0V: 5.127V (P) PCI 12.0V:12.129V (P) PCI VAUX: 5.048V (P)
IOR0 1.5V: 1.500V (P) IOR0 1.8V: 1.790V (P)
MBM>
5. Show the detailed environment of X-shelf PCI drawer 4 in cabinet 0.
MBM> sh power -ca 0 -dr 4 pci -detail
PCI Drawer: cabinet = 0, drawer = 4
Power state: ON
Temperatures(in centigrade):
PBM: 27.5 (P) PCI_0: 23.5 (P) PCI_1: 24.0 (P)
3-108

Table of Contents

Other manuals for HP AlphaServer ES80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP AlphaServer ES80 and is the answer not in the manual?

HP AlphaServer ES80 Specifications

General IconGeneral
BrandHP
ModelAlphaServer ES80
CategoryServer
LanguageEnglish

Related product manuals