4. To test the sensor, lift the bin full actuator up (see the following figure). As the actuator is lifted up, the
green sensor state indicator clears, and the toggled counter increments. When the actuator is lowered,
the state indicator illuminates green, and the toggled counter increments once more.
If the bin full sensor does not toggle, try removing the output bin bezel and testing the sensor with a
piece of paper.
If the bin full sensor still fails to respond, replace the IPTU.
If the sensor responds correctly with the output bin bezel removed, examine the output bin bezel for
proper movement of the flag and actuator assembly. If the assembly appears OK, try reinstalling the
output bin bezel.
Overfilled
Description
A tray in the product is overfilled with paper.
406 Chapter 2 Solve problems ENWW