Power Supply
MT: 300-watt ATX Power Supply – PFC/non-PFC with a 115v/230v line
switch (varies by country/region)
SFF: 250-watt Power Supply – PFC with a 115/230v line switch.
Unit Environment and
Operating Conditions
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and
cold, to ensure that unit is operated within the specified operating range.
Leave a 4 in (10.2 cm) clearance on all vented sides of the computer to permit the required
airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are
subject to each other's re-circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer.
Lint, dust and other foreign matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must
be provided on the enclosure, and the same operating guidelines listed above will still apply.
Temperature Range (MT)
Operating
41° to 95° F (5° to 35° C)
Non-operating
–22° to 140° F (–30° to 60° C)
Relative Humidity (MT)
Operating
15% to 80% (non-condensing at ambient)
Non-operating
90% (non-condensing at ambient)
Maximum Altitude
(MT)
(unpressurized)
Operating
7500 ft (2286 m)
Non-operating
15,000 ft (4572 m)
Temperature Range (SFF)
Operating
50° to 95° F (10° to 35° C)
Non-operating
–22° to 140° F (–30° to 60° C)
Relative Humidity (SFF)
Operating
10% to 90% (non-condensing at ambient)
Non-operating
5% to 95% (non-condensing at ambient)
Maximum Altitude
(SFF)
(unpressurized)
Operating
10,000 ft (3048 m)
Non-operating
30,000 ft (9000 m)
NOTE:
Operating temperature is de-rated 1.0 deg C per 1000 ft (300 m) to 7500 ft (2286 m) for MT
and 10000 ft (3000m) for SFF above sea level, no direct sustained sunlight. Maximum rate of change is
7.5 deg C/Hr for MT and 10 deg C/Hr for SFF. The upper limit may be limited by the type and
number of options installed.
System Board
Processor
Socket T; LGA775 industry standard Micro ATX form factor
Support single Intel Core 2 Duo and Core 2 Quad, Pentium dual-core, or
Celeron processors
PWM
ON – NCP5362 – 3 phase
Chipset
Intel G45 Express
Intel I/O Controller Hub 10 (ICH10R)
Super I/O
Fintek F8000
Front Side Bus Frequency
800/1066/1333 MHz
QuickSpecs
HP Compaq dx7500 Business PC
System Details
DA - 13152 Worldwide QuickSpecs — Version 9 — 3/30/2009
Page 11

Other manuals for HP Compaq dx7500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Compaq dx7500 and is the answer not in the manual?

HP Compaq dx7500 Specifications

General IconGeneral
BrandHP
ModelCompaq dx7500
CategoryDesktop
LanguageEnglish

Related product manuals