Solution: Try the following.
●
Turn the power off at the rear of the printer and disconnect the power cord. Reconnect the power
cord and turn on the printer.
●
Check that the Right Aerosol Fan cable is not damaged and is correctly connected to the
PrintMech PCA.
●
Check that there is no obstacle blocking the fan.
●
Replace the Right Aerosol Fan
Aerosol Fan and Filter on page 253.
SE 44.4:10
Cause: Right Aerosol Fan Filter blocked
Solution: Try the following.
●
Turn the power off at the rear of the printer and disconnect the power cord. Reconnect the power
cord and turn on the printer.
●
Check that the Right Aerosol Fan cable is not damaged and is correctly connected to the
PrintMech PCA.
●
If the system error persists, replace the Aerosol Filter
Aerosol Fan and Filter on page 253.
SE 45:03
Cause: Rewinder servo shutdown
Solution: Try the following.
●
Turn the power off at the rear of the printer and disconnect the power cord. Reconnect the power
cord and turn on the printer.
●
Open the Window and check for any visible obstacles restricting the movement of the Rewinder. If
there is a wrinkled mass of paper inside the paper path, open the Rear Door and clear the
obstruction.
●
Replace the Rewinder Motor
Rewinder Gear and Motor on page 271.
SE 46:03
Cause: Primer servo shutdown
Solution: Try the following.
●
Check that the Primer Arm is not damaged and there are no obstacles in its way.
●
Turn the power off at the rear of the printer and disconnect the power cord. Reconnect the power
cord and turn on the printer.
●
Replace the Primer Assembly
Primer Assembly on page 239.
SE 46:13
Cause: Primer test distance failed
ENWW
Continuable and non-continuable error codes