3. Select Reset Maintenance Kit usage to reset the Life Counter for all parts included in a Preventative
Maintenance Kit (PMK).
You can choose from the following Preventive Maintenance Kits:
●
Preventive Maintenance Kit 1 (PMK1).
●
Preventive Maintenance Kit 2 (PMK2).
NOTE: For more information about the counters that are reset, See the user guide.
It is also advisable to check the status of the Life Counters related to the other Preventive Maintenance
Kits to avoid multiple trips to the customer.
4. Select Reset usage counters to reset the Life Counter of a single part.
●
Tubes and Trailing Cable
●
Scan-Axis Belt with Tensioner
●
Scan Motor
●
Full Bleed Foams
●
Carriage
●
Service Station
●
Scanner Counters
If you replace a part, you should reset the Life Counters as follows:
Replaced part Reset Life Counters
Ink supply tubes (with trailing cables) Tubes and Trailing Cable
Belt assembly Scan-Axis Belt with Tensioner
Scan-axis motor Scan-Axis Motor
Foams Full Bleed Foams
Carriage assembly Carriage
Service station Service Station
Drop detector Drop Detector Working Time
5. Once you have selected the Life Counters to reset, a message similar to the following will be displayed
on the Front Panel. Press the OK key to reset the selected Life Counters or press Cancel to exit without
resetting the Life Counters.
Diagnostics Print
This is a set of diagnostic prints used to highlight printhead reliability, or other printer problems that can
affect the Image Quality of the printer.
To print any of the Image diagnostics prints:
ENWW Service Utilities 183