will
begin
execution
from
step
00.
Then
use
the
program
to
complete
the
table
below:
Height
Radius
Area
of
Base
Volume
25
10
? ?
8
4.5
? ?
Press
Display
25
Enter
the
height
into
the
Y-register.
10
314.16
Program
stops
to
display
the
area.
R/S
7853.98
Volume
of
first
can
is
calculated.
8
Enter
the
height
into
the
Y-register.
4.5
63.62
Program
stops
to
display
the
area.
R/S
508.94
Second
volume
is
calculated.
With
the
height
in
the
Y-register
and
the
radius
in
the
X-register,
pressing[r/s]
in
automatic
RUN
mode
calculates
the
area
of
the
can’s
base
;
the
program
stops
at
the
first
instruction
encountered.
Pressing
[R/s]again
calculates
the
volume
of
the
can
and
program
execution
stops
at
step
00,
ready
to
run
again.
In
general,
[R/s]
is
recorded
into
a
program
when
you
need
to
display
more
than
one
answer.
To
display
only
one
answer
or
the
final
answer
of
a
series,
the
[0]
[0]
instruction
in
a
pro-
gram
is
more
convenient
since
the
calculator
ends
execution
at
step
00,
ready
to
begin
again.
Pausing
During
Program
Execution
An
[[[pause
instruction
executed
in
a
program
momentarily
interrupts
program
execution
to
display
intermediate
results
that
do
not
have
to
be
written
down.
The
length
of
the
pause
is
about
one
second,
although
more
thanone
|7
instruction
can
be used
to
lengthen
the
time
if
desired.

Table of Contents