Troubleshooting/Maintenance
: Functional checks
143
Note
Normal resistance is 30 ohms +/- 10 ohms.
4
If no resistance is measured, replace the heating element.
5
Remove the thermistor connector (Figure 5-3) and measure the resistance
between pins one and two.
Note
Normal resistance is 440K ohms +/- 30K ohms at 68° F (20° C).
6
If no resistance is measured, replace the heating element.