50 Maintenance C9148-90909
Side-edge adjustment for the glass
Hint It might be helpful to reset the product settings to factory defaults before attempting manual
calibration. Be sure to print a configuration page before doing a setting reset so that any user-
defined settings can be restored (see “Configuration page” on page 130).
1 Press the
MENU button.
2 Select DIAGNOSTICS.
3 Select CALIBRATE SCANNER.
4 Select SIDE EDGE ADJUSTMENT GLASS.
5 The message Side Edge Glass ### Range 0-255 appears on the control-panel display. Use
the numeric keypad to type a value for the side-edge adjustment.
Hint Entering a lower value than current setting moves the image away from the left edge (toward the
right side of the page). Entering a higher value than the current setting moves the image toward
the left edge of the page.
6 Press the
SELECT ( ) button to save the setting.
7 Use the glass to scan a source document (use the calibration target page if you have already
automatically calibrated the MFP). Verify that the image is correctly positioned on the output
copy