13 Disconnect one connector (callout 7; J79) from the dc controller, and unwind the wire harness
from the MFP.
Figure 6-95 Remove the tray 1 feed-assembly (12 of 13)
14 Disconnect one connector (callout 8) from the tray 1 feed-assembly. Remove the tray 1 feed-
assembly.
8
Figure 6-96 Remove the tray 1 feed-assembly (13 of 13)
NOTE The grounding spring that is on the dc-controller side of the feed assembly is not
captive and can be easily lost. When you reinstall the feed assembly, make sure that the
grounding spring is correctly seated against the sheet-metal chassis.
Internal assemblies 207