Control panel message Description Recommended action
on the network might be causing the
error. Make sure to try all solutions
suggested, especially upgrading the
Jetdirect firmware.
6. Disable the print server.
For EIO print servers, remove the
card.
For embedded print servers, use
the SERVICE menu.
7. If the problem persists, contact
HP Support.
8X.YYYY EMBEDDED JETDIRECT
ERROR
The HP Jetdirect embedded print server has
encountered a critical error.
1. Turn the device off and then on.
2. Update the Jetdirect firmware.
3. If the problem persists, contact
HP Support.
<Date> <Time>
To change press
To skip, press STOP
The device has an internal clock that tracks
the date and time. You are prompted to set
the correct date and time the first time you
turn on the device.
Press to change the date and time.
Press Stop to skip this step. You can set the
date and time later by using the SYSTEM
SETUP menu.
If the prompt appears each time you turn on
the device, the clock is not working correctly.
Contact HP support.
Access Denied MENUS LOCKED The device administrator has enabled the
control-panel security mechanism. You
cannot modify control-panel settings in this
circumstance. The message disappears after
a few seconds, and the device returns to
Ready or BUSY state.
Contact the device administrator to change
settings.
ACTION NOT CURRENTLY AVAILABLE
ON TRAY X
alternates with
Tray size cannot be ANY SIZE/ANY
CUSTOM
You are trying to set duplex registration for a
tray that is configured for ANY SIZE or ANY
CUSTOM. Duplex registration is not available
when the tray size is set to either of these
settings.
Change the size setting for the tray.
CHOSEN PERSONALITY NOT
AVAILABLE
alternates with
To continue press
The device encountered a request for a
personality that did not exist in the device.
The job is cancelled and no pages are
printed.
1. Press to continue.
2. Try a different driver.
Cleaning... The device is processing the cleaning page. No action necessary.
CLOSE TOP COVER Door switch SW501 is signalling that the
cartridge door is open. If the cartridge door is
open, the main motor will not rotate during
device power-up.
The wires for switch SW501 are hard-wired
to the ECU. Verify that the wires from the
ECU are installed on the correct terminals of
switch SW501.
CLOSE TOP COVER AND FRONT DOOR Door switch SW501 is signalling that the
cartridge door is open. If the cartridge door is
The wires for switch SW501 are hard-wired
to the ECU. Verify that the wires from the
48 Chapter 2 HP LaserJet P3005 Series printers ENWW