2. Remove four screws (callout 1), the scanner cover (callout 2) and the sheet-metal plate (callout 3).
NOTE: The scanner cover and plate are removed as one assembly.
TIP: When the cover is reinstalled, make sure that the black screws (callout 4) are installed in
the correct screw holes.
Figure 2-109 Remove the duplex-reverse solenoid (2 of 5)
1
2
3
4
3. Disconnect two connectors (callout 1), and then release the wire harness (callout 2) from the guides
(callout 3).
Figure 2-110 Remove the duplex-reverse solenoid (3 of 5)
1
3
2
ENWW Main assemblies 105