52 – Control panel messages
EN
5Si
• The duplexer is defective.
– Replace the duplexer.
IID, IIID: Duplex Feed Error
• The duplex shift plate is improperly fitted.
– Check the duplex shift plate for correct position and operation.
• The PS5 or SL4 is bad.
– Verify proper operation and replace as necessary.
• There is a defect in the main motor.
– Replace the main motor or the power supply or main drive motor
PCA.
2686 D/A: Main Motor Stall
• The input tray is too full.
– Remove some of the paper.
• The fuser drive gears are bent or locked up.
– Adjust or replace the fuser drive gears.
• The main motor has problems.
– Replace the main motor.
54 Error