56 – Control panel messages
EN
• The AC kill switch operation is faulty.
• The connector J010 is improperly fitted.
• There is a bad main motor PCA or main motor.
6P, 5P, 5, 4V, 4P, 4L, 4
• The fan cable is improperly fitted.
– Check the fan cable; reseat the fan cable if necessary.
• The fan is defective.
4V
• The DC controller PCA is defective.
4Si, IIISi
• The paper cassette is improperly inserted.
5Si
• Tray/lifter malfunction.
If x=1: Tray 2 lifter malfunction.
If x=2: Tray 3 lifter malfunction.
If x=3: Tray 1 lifter malfunction.
If x=4: Tray 4 lifter malfunction.
– Press [Select] to continue.
Repair or replace the tray lifter.
58 Service
58.1 and 58.2
58.x Printer Error