Removal and replacement procedures 42
o Slide the server back into the rack.
7. Power up the server.
Standard hard drive cage backplane
To remove the component:
1. Power down the server (on page 26).
2. Do one of the following:
o Open or remove the tower bezel, as needed ("Front bezel" on page 28).
o Extend the server from the rack (on page 25).
3. Place the tower server on its side.
4. Remove the access panel ("Access panel" on page 29).
5. Disconnect all cables from the rear of the hard drive cage.
6. Remove the hard drive cage ("Standard hard drive cage" on page 38).
7. Remove all hard drives ("SAS/SATA hard drive" on page 37).
8. Remove the hard drive cage backplane:
Six-bay LFF hard drive cage backplane