Removal and replacement procedures 51
IMPORTANT: This server does not support mixing RDIMMs and UDIMMs. Attempting to mix
these two types causes the server to halt during BIOS initialization.
To identify the DIMMs installed in the server, see "DIMM identification (on page 78)."
1. Power down the server (on page 26).
2. Do one of the following:
o Unlock and remove the bezel ("Front bezel" on page 28).
o Extend the server from the rack (on page 25).
3. Remove the access panel ("Access panel" on page 29).
4. Remove the large redundant fan air baffle, if installed ("Large redundant fan air baffle" on page
31).
5. Remove the DIMM baffles ("DIMM baffle" on page 32).
6. Remove a fan, if necessary ("Fan" on page 34).
7. Open the DIMM slot latches.
8. Remove the DIMM.
To replace the component, reverse the removal procedure.
For DIMM configuration information, see the server user guide.
Heatsink
To remove the component:
1. Power down the server (on page 26).
2. Do one of the following:
o Open or remove the tower bezel, as needed ("Front bezel" on page 28).
o Extend the server from the rack (on page 25).
3. Place the tower server on its side.
4. Remove the access panel ("Access panel" on page 29).