LED Indicators and Switches
System Maintenance Switch
The system maintenance switch (SW1) is a six-position switch that is used for system
configuration. The default setting for all six positions is off. For the proper system
maintenance switch settings, refer to the labels attached to the inside of the server access
panel or refer to Table 4-11.
Table 4-11: System Maintenance Switch (SW1)
Position Description On/Off Function
1 iLO Security enable indicator Off = iLO security enabled.
On = iLO security disabled
2 Configuration lock indicator Off = System configuration can be changed.
On = System configuration is locked and cannot
be changed.
3 Rack mount indicator Off = System is in a tower configuration.
On = System is in a rack-mounted configuration.
4 Enable diskette boot
indicator
Off = Booting from diskette is controlled by
RBSU.
On = Booting from diskette is enabled and
RBSU setting is overridden.
5 Password disable indicator Off = Power-on password works normally.
On = Power-on password is disabled.
6 Invalidate configuration
indicator
Off = No function is available.
On = ROM treats system configuration as
invalid.
HP ProLiant ML370 Generation 3 Server Maintenance and Service Guide 4-17