16. Remove the doctor blade and two screws. 17. Clean out all the remaining toner from the hopper. Make
sure the magnetic roller seals and the doctor blade seals are
all clean.
18. Fill the hopper with the appropriate amount of P1006
toner.
UNINET IMAGING INC. BROTHER 1240/1650 ASSEMBLING THE TONER CARTRIDGEUNINET IMAGING INC. BROTHER 1240/1650 DISASSEMBLING THE TONER CARTRIDGE
HP P1006 SERIES CARTRIDGE REMANUFACTURING INSTRUCTIONS
© 2010 UniNet Imaging Inc. All trademark names and artwork are property of their respective owners. Product brand names mentioned are intended to show compatibility only.
UniNet Imaging does not warrant downloaded information. Unauthorized sale, reproduction or distribution of this article is prohibited. For additional support, please contact techsupport@uninetimaging.com